Detroit Radiant Products DES 20-75 Installation, Operation, Maintenance And Parts Manual

Des series 4 inch tube heater

Advertisement

Quick Links

DES Series - 4" Tube Heater Installation, Operation, Maintenance and Parts Manual
WARNING:
This heater must be installed and serviced by trained gas installation and service personnel only!
!
Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death.
Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
Protect yourself and others by observing all safety information. Retain instructions for future reference.
*
For complete installation instructions, see the General Manual that accompanied this piece. Also available at www.reverberray.com.
DES Series
Project: _____________________________Date: _________________
Location: __________________________________________________
City: ________________________ State: ________ Zip: ___________
Contractor: _________________________________________________
Engineer: __________________________________________________
Local Representative: ________________________________________
Customer Name: ____________________________________________
Address: ___________________________________________________
City: ________________________ State: ________ Zip: ___________
Model #: ___________________________ Phone#: ________________
Serial #: ___________________________ Date of Install: __________
Notes: _____________________________________________________
Models
Gas Type
Qty.
Model #
BTU/H
(circle one)
DES 20-50
N or LP
50,000
DES 20-60
N or LP
60,000
DES 20-75
N or LP
75,000
DES 30-50
N or LP
50,000
DES 30-60
N or LP
60,000
DES 30-75
N or LP
75,000
DES 30-100
N or LP
100,000
DES 40-50
N or LP
50,000
DES 40-60
N or LP
60,000
DES 40-75
N or LP
75,000
DES 40-100
N or LP
100,000
DES 40-125
N or LP
125,000
DES 40-150
N or LP
150,000
DES 50-100
N or LP
100,000
DES 50-125
N or LP
125,000
DES 50-150
N or LP
150,000
DES 50-175
N or LP
175,000
DES 60-125
N or LP
125,000
DES 60-150
N or LP
150,000
DES 60-175
N or LP
175,000
*
Model requires 5EA-SUB accessory package.
Typical
Straight
U-Tube
Mount
Length
Length
Weight
Height
21'-7'
13'-0"
120 #
10' - 15'
21'-7'
13'-0"
120 #
11' - 18'
21'-7'
13'-0"
120 #
12' - 20'
31'-3'
*17'-8"
120 #
10' - 15'
31'-3'
*17'-8"
160 #
11' - 18'
31'-3'
*17'-8"
160 #
12' - 20'
31'-3'
*17'-8"
160 #
13' - 23'
40'-11'
22'-8"
190 #
10' - 15'
40'-11'
22'-8"
190 #
11' - 18'
40'-11'
22'-8"
190 #
12' - 20'
40'-11'
22'-8"
190 #
13' - 23'
40'-11'
22'-8"
190 #
15' - 25'
40'-11'
22'-8"
190 #
16' - 30'
50'-7'
*27'-4"
235 #
13' - 23'
50'-7'
*27'-4"
235 #
15' - 25'
50'-7'
*27'-4"
235 #
16' - 30'
50'-7'
*27'-4"
235 #
17' - 35'
60'-3'
32'-4"
235 #
15' - 25'
60'-3'
32'-4"
235 #
16' - 30'
60'-3'
32'-4"
235 #
17' - 35'
Warranty registration options:
1. Register online at www.reverberray.com/warranty
2. Complete the information above and fax to Detroit Radiant Products Co.
3. Complete the information above and mail to Detroit Radiant Products Co.
Printed in U.S.A.
© 2002 Detroit Radiant Products
21400 Hoover Rd., Warren, MI 48089
T. (586) 756-0950
Form# LIODES-2M-12/02 (ID)
Replaces Form# LIODES-2M-05/01
Models
Warnings
Clearances to Combustibles
Product Summary
Product Instructions
Heater Requirements
Theory of Operation
Wiring Diagrams
Flowchart
Parts Listing
Series Kit Contents
Combustion
Radiant
Chamber
Emitter Tube
Aluminized
4" Hot-rolled
Aluminized
4" Hot-rolled
Aluminized
4" Hot-rolled
Aluminized
4" Hot-rolled
Aluminized
4" Hot-rolled
Aluminized
4" Hot-rolled
Aluminized
4" Hot-rolled
Aluminized
4" Hot-rolled
Aluminized
4" Hot-rolled
Aluminized
4" Hot-rolled
Aluminized
4" Hot-rolled
Aluminized
4" Hot-rolled
Titanium
4" Hot-rolled
Aluminized
4" Hot-rolled
Aluminized
4" Hot-rolled
Titanium
4" Hot-rolled
Titanium
4" Hot-rolled
Aluminized
4" Hot-rolled
Titanium
4" Hot-rolled
Titanium
4" Hot-rolled
F. (586) 756-2626
*
Table of Contents
Page
5-7
8-9
10-11
"Type" Tube
"Type" Tube
Pkg #1
Pkg. #2
Pieces
20-4 Alum-HRT
N/A
20-4 Alum-HRT
N/A
20-4 Alum-HRT
N/A
30-4 Alum-HRT
N/A
30-4 Alum-HRT
N/A
30-4 Alum-HRT
N/A
30-4 Alum-HRT
N/A
40-4 Alum-HRT
N/A
40-4 Alum-HRT
N/A
40-4 Alum-HRT
N/A
40-4 Alum-HRT
N/A
40-4 Alum-HRT
N/A
40-4 Titan-HRT
N/A
40-4 Alum-HRT
10-4-HRT
40-4 Alum-HRT
10-4-HRT
40-4 Titan-HRT
10-4-HRT
40-4 Titan-HRT
10-4-HRT
40-4 Alum-HRT
20-4-HRT
40-4 Titan-HRT
20-4-HRT
20-4-HRT
40-4 Titan-HRT
1
2
2
3
3
4
4
12
Baffle
5
5
5
4
4
4
5
2
2
2
4
4
4
2
4
4
2
2
2
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DES 20-75 and is the answer not in the manual?

Questions and answers

Summary of Contents for Detroit Radiant Products DES 20-75

  • Page 1 Model requires 5EA-SUB accessory package. Warranty registration options: 1. Register online at www.reverberray.com/warranty 2. Complete the information above and fax to Detroit Radiant Products Co. 3. Complete the information above and mail to Detroit Radiant Products Co. Printed in U.S.A.
  • Page 2: Mounting Angle

    DES Series - 4” Tube Heater Installation, Operation, Maintenance and Parts Manual DES Series CLEARANCES TO COMBUSTIBLES (IN.) WARNING! SIDE MOUNTING MODEL NO. BELOW NOT FOR RESIDENTIAL USE! ANGLE FRONT BEHIND Do not use in the home, sleeping quarters, DES(20,30,40)-50 [N,P] 0º...
  • Page 3: Tube Installation Sequence

    DES Series - 4” Tube Heater Installation, Operation, Maintenance and Parts Manual DES Series Mechanical Instructions This supplement is designed to address the specifics of the DES Series - See page 12 for specific product features. Product Summary DES Series heaters are available from 20 to 60 foot, 50,000 to 175,000 BTU’s, natural or LP gas. DES Series are positive pressure, single stage heaters and feature hot-rolled steel for it’s radiant pipes.
  • Page 4: Electrical Requirements

    DES Series - 4” Tube Heater Installation, Operation, Maintenance and Parts Manual DES Series Electrical Requirements Theory of Operation Starting Circuit · (see internal wiring diagrams) ♦ 120 Volt - 60 HZ, single phase, 3-wire. ♦ 25V thermostat connection. When voltage is applied to L1 and L2, a circuit is ♦...
  • Page 5: Internal Wiring Diagrams

    DES Series - 4” Tube Heater Installation, Operation, Maintenance and Parts Manual Internal Wiring Diagrams DES LADDER DIAGRAM 120VAC BLOWER PRESSURE SWITCH IGNITOR/SENSOR GAS VALVE IGNITION MODULE IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 C.
  • Page 6: Field Wiring Diagrams

    DES Series - 4” Tube Heater Installation, Operation, Maintenance and Parts Manual DES Series Field Wiring Diagrams 24V T-stat WHITE TO HEATER BRANCH #1 115V Common required for thermostats that require constant power. WHITE BY OTHERS TO HEATER BRANCH #2 115V POLE POLE...
  • Page 7: Alternative Wiring Diagrams

    DES Series - 4” Tube Heater Installation, Operation, Maintenance and Parts Manual Alternative Wiring Diagrams THIS PAGE INTENTIONALLY LEFT BLANK. THERE ARE NO ALTERNATIVE WIRING DIAGRAMS FOR THE DES SERIES...
  • Page 8 DES Series - 4” Tube Heater Installation, Operation, Maintenance and Parts Manual...
  • Page 9 DES Series - 4” Tube Heater Installation, Operation, Maintenance and Parts Manual...
  • Page 10: Parts Breakdown

    DES Series - 4” Tube Heater Installation, Operation, Maintenance and Parts Manual DES Series Parts Breakdown...
  • Page 11: Basic Parts List

    DES Series - 4” Tube Heater Installation, Operation, Maintenance and Parts Manual Basic Parts List...
  • Page 12: Product Features

    DES Series - 4” Tube Heater Installation, Operation, Maintenance and Parts Manual Kit Contents & Product Features Kit contents for the DES Series are shown below. Reference the proper column for your particular models length. FILLED BY: DES SERIES KIT CONTENTS DESCRIPTION 20 FOOT 30 FOOT...

Table of Contents