SAVING SETTINGS
Go to "SAVE CHANGES" to enable the chosen setup (wait
for completion of the save procedure). You must also dis-
able the Mail Server in this table (in all languages).
RESTORING SETTINGS
To restore the projector's network setting to the default fac-
tory setting click on "Restore". Wait for completion of the
restore procedure.
Email Configuration
Enable
SMTP Mail Server:
172.031.127.066
Domain Name:
Mail Server:
SMTP Port:
00025
Recipient Address:
support@mail.it
EMAIL SETTINGS
This screen is used to define the operating parameters for
notification of the projector status by e-mail.
Enabled:
notification service by email is enabled.
Disabled:
notification service by email is disabled.
Domain name, SMTP Mail Server: parameters to be en-
tered according to the specific network settings to which
the HT3000 HOST projector is connected.
IMPORTANT:
To save the network settings the projector needs to
be rebooted, set the system to standby and wait for
the cooling sequence to complete. Once the fans
have stopped power off the HOST and Projector via
main power switch. Wait 5 seconds and Power on the
projector and HOST.
DESCRIPTION OF THE NOTIFICATION MAIL SENT
BY THE PROJECTOR
If the email notification service is enabled, the projector will
automatically send an email to the specified address when
the following circumstances occur:
Downloaded From projector-manual.com Sim2 Manuals
Disable
Apply Settings
Factor Settings
1. Cooling fan error (Error Code 1)
2. Temperature too high (Error Code 2)
3. Lamp error (Error Code 3)
4. Communication error (Error Codes 4 e 5)
Email sender:
"CCCCCCCCCCCCCCCCCCCExxx"
C: serial code of the projector sending the notification
X: error code
Email subject:
"WWWWWLLLLLFFFFFFXXXYYY#
W: Total hours of projector use
L: Hours projector lamp on
F: Software firmware version
X: Operating status:
0 – OFF
1 – ON
2 – Lamp preheating
3 – Lamp switching back on
4 – Lamp cooling
Y: Specific status: