ABB Tropos 6410 Installation Manual page 30

Networks mesh router outdoor
Table of Contents

Advertisement

Note
Only use shielded Cat5, Cat5e, or Cat6 cable rated for outdoor use. For protection against risk of fire,
electrical hazard and to ensure the reliable operation of this equipment, the shields of the Cat5 cable must
be properly terminated and bonded to the unit and to the protective earth (PE) at the building entrance.
Note
National Electrical Codes (NEC) Article 800 requires the use of Agency Listed (UL/CSA) Building Entrance
Protector for all power and communications cables entering a building. The NEC intends by Article 800 to
protect the building and occupants from fires caused by transient voltage and current surges.
Warning
DC voltage may be present on RJ45 pins 4,5 (+) and 7,8 (-).
Attention
Une tension continue peut être présente sur les broches RJ45 4, 5 (+) et 7, 8 (-).
Note
This is not a mid-span powered device. Never attempt to daisy-chain Power Over Ethernet devices.
Connecting the Ethernet cable through the watertight gland
Use the following procedure to connect an Ethernet cable and RJ-45 connector to either the LAN
or MGT port. Use the pin assignments in
Have the Ethernet data cable, nut, rubber boots, and cable gland available.
1.
Remove the cable gland from the bottom of the router. Determine the port to use (see
2.
Figure
3.
Press the tab on the RJ45 connector down as you push the cable through the nut. Make sure
that the orientation is consistent with
Separate the rubber boot as needed and slide the connector through the boot. Use the boot
4.
with the smaller diameter opening, unless the cable is too wide to permit the boot to close
completely.
Slide the cable through the cable gland, as shown in
5.
Tropos Routers Installation Guide, Models 6410 and 6420
11).
Table
3.
Figure
10.
Figure
10.
Chapter 2
30