11-5. Filter replacement

Purafil accelerator, HEPA filter, clear filter, which consist of triple structure of deodorizing filter is used for
filtering out contaminants, which occurs from a printer of FFF type in Cubicon single plus.
Contaminants of the clean filter may cause not only poor filter performance but also filter fan operation
interference and lead to the product malfunction.
Do not cleanse polluted clean filter. But replace it with new one.
Replacement period of the clean filter depends on the product use environment and user's printing habit.
Generally, it is recommended to replace the clean filter every six months.
Make sure to install the clean filter to a case in appropriate direction. Inappropriate installation may
lead to poor filter performance and a fan malfunction.
11-6. Rubber brush & wire brush replacement period and method
Heat resisting rubber cleaning brush and wire brush are attached to the left side of heating bed for cleaning
the end part of nozzle. Make sure to remove filament leftover as it may cause secondary nozzle pollution.
Those two brushes are consumable products. Therefore, user can replace those products through designated
A/S center in the case of product damage.
Replacement period of nozzle cleaning brush is when the brush cannot function properly due to filament
leftover and the brush replacement is required in this case. Continuous brush use without replacement may
lead to auto leveling failure and nozzle shock.
① Press fixture to the bottom part of rear socket and pull out
socket
② Take out the bed by pulling it up
Bottom part fixture
Rotate
and
counterclockwise direction.
52
CUBICON Single Plus
Pull out
untie
the
bed
in