3.2

Category 1 parameters: Room Thermostat Settings

Parameter
Para
meter
N:o
AM-PM / 24hr
1:CL
Display
Reset Time/ Temp
2:rP
Program
Upper Temp Limit
6:uL
Lower Temp Limit
7:LL
Temperature Offset
12:tO
Proportional Band
13:Pb
Width
Room control / OTC
14:rC
1)
OTC heat curve
15:OC
Reset Parameters
19:FS
to Factory Defaults
Factory Default Setting
Display
Description
24
24 hr clock display
format
1
Time / Temperature
profile set to factory
default. Changes to
0 when one of the
time/temp profiles
are changed.
35
35°C Upper Temp.
Limit
5
5°C Lower Temp.
Limit
0
No temperature
offset
1.5
Proportional band of
1.5 degree
0
Room temperature
control (thermostat)
10
1
All settings at factory
defaults Changes to
0 when one of the
parameter is
changed
12
Optional Setting
Display
Description
12 hr – AM/PM clock display
12
format
0
Factory Time / Temperature
profile has been modified
To restore the factory profile
set to 1
21 to 34
21°C to 34°C, adjustment in
1°C steps
6 to 21
5°C to 21°C, adjustment in
1°C steps
-3 to +3
-3°C to +3°C, adjustment in
0.1°C steps
1.6 to 3.0
1.6°C to 3.0°C, adjustment
in 0.1°C steps
1 – OTC control without room
1 or 2
temperature compensation
2 – OTC control with room
temperature compensation
1 to 40
1 to 40 adjustment in
steps of 1
0
Settings are as modified
above. To restore the factory
parameters set to 1