OPERATING MODE DESCRIPTION

AUTO restart
• The same mode/ fan speed/set temperature/swing angle as prior to the power cut are restored.
COOL mode
• Press SWING button to change up/down air flow direction.
Press FAN button to change the fan speed of the indoor unit.
Press the TEMPERATURE ADJUSTMENT button to change the temperature setting.
DRY mode
• Indoor fan motor control
In Dry mode, the fan motor runs at low speed.
When the compressor switches off, the indoor fan continues running.
• In Dry mode, the temperature settings remain the same, but 2°C lower than the previous temperature.
• Compressor control
When the room temperature is below 16°C, the compressor is off.
When it is over 16°C, the compressor runs intermittently, with operation periods depends on the
temperature setting and the room temperature.
When the room temperature is over or equal to 23 °C, the compressor runs for 8 mins and remains off
for 3 mins.
When the room temperature is below 23, the compressor runs for 2 mins and remains off for 3 mins.
When the room temperature is lower than the set temperature, the compressor runs for 1 min and
remains off for 4 mins.
FAN mode
• In this mode, the indoor unit operates like a fan only.
When the fan speed is set to Auto, the fan speed is low.
Press SWING button to change up/down air flow direction.
Press FAN button to change the fan speed from Low-Med.-High of the indoor unit.
HEAT mode (heat pump type)
• Press SWING button to change up/down air flow direction.
Press FAN button to change the fan speed of the indoor unit.
Press ROOM TEMPERATURE ADJUSTMENT button to change the temperature setting.

SLEEP mode

• When this button is pressed, the fan speed is low. In sleep mode, the temperature setting increases (in
cooling mode) by 1°C or decreases (in heating mode) by 2°C per hour automatically. After 2 hours, the
temperature setting remains at the user temperature setting +2°C (in cooling mode) and -4°C (in
heating mode). When the room temperature is lower (in cooling mode) or higher (in heating mode)
than the set temperature, the compressor stops until the room temperature is higher (in cooling mode)
or lower (in heating mode) than the set temperature.
DEFROST
A. Defrosting is activated: in the presence of both of the conditions listed below.
• When the compressor has been running for 40 mins;
• The temperature of the outdoor pipe OPT ≤ -4°C and has been running for 1min.
B. Defrosting is ended: in the presence of one of the conditions listed below.
• The temperature of outdoor pipe OPT ≥ 15°C and has been running for 1min.
• Defrosting has been active for over 10 mins.
JET mode
Used to activate rapid cooling. Rapid cooling operates at high fan speed with 16°C as automatic set
temperature. If you press the on/off button when the appliance is running, it will be stopped. When the
room temperature is lower than the set temperature (16°C), the compressor stops, fan speed remains
high.