ID Switch
ID switch
When you have connected the main unit and the subunits, you have to set
the IDs of the main unit and the subunits using the "unit ID switch" on the
units.
You set the main unit to "3", subunit 1 to "1" and subunit 2 to "2".
You have to use a small screwdriver to move the arrow on the ID switch to
the required ID number.
Note
If your headend system consists of only one unit you have to set the
ID of the unit to"0".
In case you need to reset the IP address of a headend unit, i.e. to return to
the factory default address, you use the ID switch.
To return to factory default settings do the following:
• Switch off the power to the main unit.
• Set the ID switch on the main unit to "7", then switch on the power.
The four LEDs flash red and yellow until the process of resetting the IP
address has been completed.
If the reset process has been successful the LEDs will turn green.
If the reset process fails the LEDs will turn red.
• Switch off the power to the main unit.
• Set the ID switch on the main unit back to the initial setting.
• Switch on the power to the main unit.
Now you have reset the IP address to the factory default address.
For information about how to change a default IP address, see "IP settings"
on page 33.
18