The Series 616W Differential Pressure Transmitter senses the
pressure of air and non-combustible, compatible gases and sends a
standard 4-20 mA output signal.
All models, including those featuring LCD digital read-out, are factory
calibrated to specific ranges, as listed in the chart on the next page.
Positive, negative and differential pressures can be measured within a
full span accuracy of ±0.25%. This weatherproof unit is enclosed in a
polycarbonate case, rated (IP66/NEMA 4X).
The Span and Zero controls are for use when checking calibration. They
are not intended for re-ranging to a significantly different span.
DWYER INSTRUMENTS, INC.
1.800.561.8187
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A.
Series 616W Differential Pressure Transmitter
Specifications - Installation and Operating Instructions
3-1/8
[79.38]
3-3/4
[95.25]

SPECIFICATIONS

Service: Air and non-combustible, compatible gases.
Wetted Materials: Consult factory.
Accuracy: ±0.25% F.S., display accuracy ±0.5%.
Stability: ±1% F.S./yr.
Temperature Limits: 0 to 140°F (-17.8 to 60°C).
Compensated Temperature Limits: 20 to 120°F (-6.67 to 48.9°C).
Pressure Limits: See chart.
Thermal Effect: ±0.02% F.S./°F (0.0012% F.S./°C).
Power Requirements: 10-35 VDC (2-wire).
Output Signal: 4 to 20 mA.
Zero and Span Adjustments: Potentiometers for zero and span.
Loop Resistance: DC; 0-1250 ohms maximum.
Current Consumption: DC; 38 mA maximum.
Electrical Connections: Screw-type terminal block.
Process Connections: Barbed, dual size to fit 1/8˝ and 3/16˝
(3.12 and 4.76 mm) I.D. rubber or vinyl tubing.
Enclosure Rating: NEMA 4X (IP66).
Mounting Orientation: Vertical, consult factory for other position
orientations.
Weight: Without LCD 8.8 oz (249 g); with LCD 9.6 oz (272 g).
Agency Approvals: CE.
Phone: 219/879-8000
Fax: 219/872-9057
www.
.com
Ø3/16 [4.76]
MOUNTING HOLES
TYP 4 PLACES
1-1/4
[31.75]
4-1/2
[114.30]
1-5/16
[33.32] TYP
5-1/8
7/16 OR 5/8
[130.18]
[11.13 OR 15.88] TYP
1/8 AND 3/16
[3.18 AND 4.76]
I.D. TUBING
1-3/16
[30.18]
3/4 [19.05] TYP
2-1/8
[53.98]
Fig. A
www.dwyer-inst.com
information@itm.com
e-mail: info@dwyer-inst.com
Bulletin E-43-W
4-17/32
[115.09]
3-1/8
[79.38]

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 616W Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dwyer Instruments 616W Series

  • Page 1 Enclosure Rating: NEMA 4X (IP66). Mounting Orientation: Vertical, consult factory for other position orientations. Weight: Without LCD 8.8 oz (249 g); with LCD 9.6 oz (272 g). Agency Approvals: CE. DWYER INSTRUMENTS, INC. Phone: 219/879-8000 www.dwyer-inst.com 1.800.561.8187 information@itm.com P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A.
  • Page 2 Series 616W Transmitter Models & Ranges Digital Digital Pressure Maximum Pressure Maximum Model Display Display Range Pressure Model Range Pressure 0-1.00 616W-00 0-1 in.w.c. 2 psig 616W-00-LCD 0-1 in.w.c. 2 psig 616W-0 0-2.00 0-2 in.w.c. 2 psig 616W-0-LCD 0-2 in.w.c. 2 psig 0-3.00 616W-1...
  • Page 3 Calibration Check - Each Series 616W Transmitter is factory calibrated MULTIPLE RECEIVER INSTALLATION to the range given in the model chart. To check calibration and adjust if An advantage of the standard 4-20 mA DC output signal produced by the necessary, the following procedure should be used.
  • Page 4 ©Copyright 2010 Dwyer Instruments, Inc. Printed in U.S.A. 6/10 FR# 01-440886-01 Rev. 4 DWYER INSTRUMENTS, INC. Phone: 219/879-8000 www.dwyer-inst.com 1.800.561.8187 information@itm.com P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A. Fax: 219/872-9057 e-mail: info@dwyer-inst.com www. .com...

Table of Contents