Toshiba MML-AP0124H2UL Service Manual page 56

Carrier
Hide thumbs Also See for MML-AP0124H2UL:
Table of Contents

Advertisement

L
g i
t h
b
o l
c
k
C
Operation Timer
Ready
Alternate blinking
Operation Timer
Ready
Alternate blinking
Operation
Timer
Ready
Synchronized blinking
Operation Timer
Ready
Blinking
Operation
Timer
Ready
Synchronized blinking
Operation
Timer
Ready
Synchronized blinking
h
e
c
k
c
o
d
e
F01
Heat exchanger temperature sensor (TCJ) trouble
F02
Heat exchanger temperature sensor (TC2) trouble
F03
Heat exchanger temperature sensor (TC1) trouble
F10
Ambient temperature sensor (TA/TSA) trouble
F11
Discharge temperature sensor (TF) trouble
F04
Discharge temperature sensor (TD1) trouble
F05
Discharge temperature sensor (TD2) trouble
F06
Heat exchanger temperature sensor (TE1, TE2) trouble
F07
Liquid temperature sensor (TL1, TL2, TL3) trouble
F08
Outside air temperature sensor (TO) trouble
F12
Suction temperature sensor (TS1,TS3) trouble
F13
Heat sink sensor (TH) trouble
Wiring trouble in heat exchanger sensor (TE1) and liquid temperature sensor (TL1)
F15
Outdoor unit temperature sensor wiring/installation trouble
Wiring trouble in outdoor high pressure sensor (Pd) and low pressure sensor (Ps)
F16
Outdoor pressure sensor wiring trouble
F17
Outside air suction temperature sensor (TOA) trouble
F18
Indoor air suction temperature sensor (TRA) trouble
F23
Low pressure sensor (Ps) trouble
F24
High pressure sensor (Pd) trouble
F29
Fault in indoor EEPROM
H01
Compressor breakdown
H02
Compressor lockup
H03
Current detection circuit trouble
H05
Wiring/installation trouble or detachment of outdoor discharge temperature sensor (TD1)
H06
Abnormal drop in low-pressure sensor (Ps) reading
H07
Abnormal drop in oil level
H08
Trouble in temperature sensor for oil level detection circuit (TK1, TK2, TK4 or TK5)
H15
Wiring/installation trouble or detachment of outdoor discharge temperature sensor (TD2)
H16
Oil level detection circuit trouble - Trouble in outdoor unit TK1, TK2, TK4 or TK5 circuit
L02
Outdoor unit model unmatched trouble
L03
Duplicated indoor group header unit
L05
Duplicated priority indoor unit (as displayed on priority indoor unit)
L06
Duplicated priority indoor unit (as displayed on indoor unit other than priority indoor unit)
L07
Connection of group control cable to stand-alone indoor unit
L08
Indoor group address not set
L09
Indoor capacity not set
L04
Duplicated outdoor refrigerant line address
L10
Outdoor capacity not set
L20
Duplicated central control address
L23
SW setting mistake
L24
Flow selector unit(s) setting trouble
L28
Too many outdoor units connected
L29
Trouble in number of IPDUs
L30
Indoor external interlock trouble
C
a
u
s
e
f o
– 56 –
a f
u
t l
Indoor unit temperature sensor
troubles
Outdoor unit temperature
sensor troubles
Outdoor unit pressure sensor
troubles
Outdoor unit compressor or
A-3-IPDU related troubles
Protective shutdown of outdoor
unit

Advertisement

Table of Contents
loading

Table of Contents