NETGEAR 24-Port Gigabit Smart Managed Pro Switch with PoE+ and 2 SFP Ports Model GS724TPv2
Host Timeout. Specify the time that the switch must wait for a report for a particular
group for the specified VLAN ID. The valid range is the value in the Maximum
Response Time plus 1 to 3600 seconds. The default is 260 seconds.
Maximum Response Time. Specify the time that the switch must wait after sending a
query for the specified VLAN ID if the switch does not receive a report for a particular
group for that VLAN ID. Enter a value between 1 and 25 seconds. The default is 10
seconds. The configured value must be less than the value in the Host Timeout field.
MRouter Timeout. Set the value for multicast router expiry time of IGMP snooping for
the specified VLAN ID. The valid range is 0 to 3600 seconds. The default is 0
seconds.
Querier Mode. Enable or disable the IGMP Querier Mode for the specified VLAN ID.
The default is Disable.
Query Interval. Set the IGMP query interval for the specified VLAN ID. The valid
range is 1 to 1800 seconds. The default is 60 seconds.
7.
Click the Apply button.
The updated configuration is sent to the switch. Configuration changes take effect
immediately.

Modify IGMP Snooping Settings for a VLAN

To modify IGMP snooping settings for a VLAN:
1.
Connect your computer to the same network as the switch.
You can use a WiFi or wired connection to connect your computer to the network, or
connect directly to a switch that is off-network using an Ethernet cable.
2.
Launch a web browser.
3.
In the address field of your web browser, enter the IP address of the switch.
If you do not know the IP address of the switch, see
Switch
on page 9.
The login window opens.
4.
Enter the switch's password in the Password field.
The default password is password.
The System Information page displays.
5.
Select Switching > Multicast > IGMP Snooping > IGMP Snooping VLAN Configuration.
The IGMP Snooping VLAN Configuration page displays.
6.
Select the check box next to the VLAN ID.
7.
Update the values.
8.
Click the Apply button.
The updated configuration is sent to the switch. Configuration changes take effect
immediately.