Table 1002. TCAS Line Maintenance Troubleshooting Procedure
(Fault Indication on PPI or Dedicated Display)
Fault Annunciation
TCAS PROCESSOR
UPPER ANTENNA
LOWER ANTENNA
ATTITUDE
HEADING
TCAS FAIL/NO TCAS
TRAFFIC DISPLAY
RA DISPLAY No. 1
RA DISPLAY No. 2
RA DISPLAY No. 1 and No. 2
RADIO ALT No. 1 and No. 2
TD FAIL
NOTE: If fault is shown, do front-panel test of TCAS processor (paragraph 2.C.) to make these
problems clear.
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
MAINTENANCE MANUAL
CAS-100 COLLISION AVOIDANCE SYSTEM
Do the TCAS processor self test
(paragraph 2.C.) for specifics.
PPI or dedicated display failure.
One RA DISPLAY or RADIO ALT FAULT will not
show in a two system display unless other faults are
shown.
Check ADCs, VSIs, wiring, power.
Check the two radio altimeters.
PPI defective.
Remedy