Pairing/Cutting Out Of The Remote Controls; Pairing/Cutting Out Of The Electronic Keys Chd 400; Emergency Desactivation; Use Of The Main And Personal Code - MED 2200 User Manual

Modular alarm unit with med remote control
Table of Contents

Advertisement

Available languages

Available languages

PAIRING/CUTTING OUT OF THE REMOTE CONTROLS:

With the system in off position, enter the EMERGENCY CODE (MAIN CODE or PERSONAL
one) as shown on the PIN CARD. When the confirmation BEEPS end and the LED is switched
on fixed again, within 20 seconds press for three times consecutively the button of each remote
control to be activated or to keep working, waiting each time the LED relighting and the BEEP
from the buzzer. 3 close BEEPS and 3 flashings confirm the read in of the remote control.
Once activated the last one (maximum 3 simultaneously), turn on/off the ignition key one time or
wait for 30 seconds.
WARNING:
- The unused remote controls
activated again by repeating the procedure.
- The procedure can be cut off only in the initial phase, only if the button of the first remote
control has been pressed for maximum 2 times.
- After 20 seconds without doing anything the procedure is quitted.
- The denial on the programming of further remote controls is signalised by 2 close BEEPS.
- Once activated the procedure, it is possible to learn the electronic keys, to create or change
the PERSONAL CODE, before quitting.

PAIRING/CUTTING OUT OF THE ELECTRONIC KEYS CHD 400:

With the system in off position enter the EMERGENCY CODE (MAIN CODE or PERSONAL
CODE) as shown on the PIN CARD.
When the confirmation BEEPS end and the LED is switched on fixed again, within 15 seconds
press on the key socket for 3 close times the metallic part of
or to keep working, waiting each time the LED relighting and the BEEP from the buzzer.
If the contact is not close enough, although the confirmation signal, it could be necessary to
press the key again: only 3 close BEEPS and 3 LED flashings indicate the correct read in.
Once activated the last one (maximum 2 simultaneously), turn on/off the ignition key one time or
wait for 30 seconds.
WARNING:
- The unused keys during this
repeating the procedure
- The procedure can be cut off only in the initial phase, only if the first key has been pressed for
maximum 2 times.
- After 20 seconds without doing anything the procedure is quitted.
- The denial on the programming of further keys is signalised by 2 close BEEPS.
- Once activated the procedure, it is possible to learn the remote controls, to create or change
the PERSONAL CODE, before quitting

EMERGENCY DESACTIVATION

The system can be desactivated and the engine can be started also without the remote control
using the following procedure shown on the
PERSONAL CODE), or using the emergency electronic key

USE OF THE MAIN AND PERSONAL CODE

1
Remove the PIN CARD label: the main code is now shown.
2
Insert the ignition key and turn it one time on/off to switch the LED on (red pilot light).
3
Before the LED is switched off, press its button as many times as the first number of the code;
each time the LED switches off to confirm.
4
Wait until the LED is off and on again.
5
Repeat the 3-4 steps for each remaining code numbers.
The usual desactivation signal confirms the operation has been completed successfully.
during this operation are desactivated; they can be
operation are desactivated; they can be activated again by
.
START THE ENGINE WITHIN 10 MINUTES
PRESS THE BUTTON ONLY WHEN THE LED IS ON.
each key CHD 400 to be activated
PIN CARD
too (using the MAIN CODE or the
CHD 400
(optional).
20

Hide quick links:

Advertisement

Table of Contents
loading