General-Purpose I/O Ports - Contec PT-310LS User Manual

Fanless, arm cortex-a8, sd, 12.1 inch 310 series
Table of Contents

Advertisement

General-purpose I/O ports

The unit has four channels of general-purpose isolated I/O port.
Refer to the software manual for programming this ports.
Table 4.9. General-purpose I/O ports connector
NoPin No.
Signal name
1
2
3
4
5
6
7
8
9
10
Connector: 15EDGRC-3.5-10P-14 (DEGSON ELECTRONICS CO.,LTD)
Cable connector: 15EDGK-3.5-10P-14 (DEGSON ELECTRONICS CO.,LTD)
Specifications
[Input section]
-
Input specification
-
Input resistance
-
Input protection circuit
-
Input response time
-
External circuit power supply
[Output section]
-
Output specification
-
Output rating
-
No. of output signals
-
Output response time
PT-310 User's manual
10
↓ Front(LCD) side
General-purpose input
PI_PCOM
(plus common)
PI(0)
General-purpose Input 0
PI(1)
General-purpose Input 1
PI(2)
General-purpose Input 2
PI(3)
General-purpose Input 3
PO(0)
General-purpose Output 0
PO(1)
General-purpose Output 1
PO(2)
General-purpose Output 2
PO(3)
General-purpose Output 3
General-purpose Output
PCOM_PO
(minus common)
: Optocoupler isolated current drive input
: 1.1kΩ
: Reverse-connection protection diode provided
: Within 200 µsec
: 12V - 24VDC (±10%)
: Optocoupler isolated open-collector output
: 30VDC, 40mA max.
: 4
: Within 200 µsec