Remove And Replace The Power Supply Module - Cisco Firepower 4100 Series Hardware Installation Manual

Hide thumbs Also See for Firepower 4100 Series:
Table of Contents

Advertisement

Maintenance and Upgrades
Do not switch the 2 SSDs. The MSP MUST be installed in slot 2. If you remove it and install it in slot 1,
Caution
all stored file capture data is lost.
Step 1
Save your configuration.
Step 2
Power down the chassis by moving the power switch to the OFF position. See
Appliance, on page 1
Step 3
To remove an SSD, face the front of the chassis, loosen the 2 captive screws on the SSD, and gently pull it out of slot 1
of the chassis.
Figure 43: Remove the SSD
Step 4
To replace the SSD, make sure the power switch is still in the OFF position, and then hold the SSD in front of slot 1 and
push it in gently until it is seated.
Step 5
To install the MSP SSD, make sure the power switch is still in the OFF position and then remove the blank faceplate in
Slot 2 by loosening the captive screws on either side of the faceplate.
Step 6
Hold the MSP SSD in front of slot 2 and push it in gently until it is seated.
Do not switch the 2 SSDs. The MSP MUST be installed in slot 2. If you remove it and install it in slot 1, all
Caution
stored file capture data is lost.
Step 7
Tighten the captive screws on either side of the SSD.
Step 8
Verify that the SSD is operational by checking the SSD LED. See
the fan LEDs.

Remove and Replace the Power Supply Module

Take note of the following warnings:
for more information about the power switch.
Remove and Replace the Power Supply Module
About the Cisco Firepower 4100 Security
Front Panel LEDs, on page 7
Cisco Firepower 4100 Series Hardware Installation Guide
for a description of
65