Optics; Flux Budget Calculation; Optical Safety; Table 8: Sample Flux Budget Calculation - Focal 914-HDE User Manual

Fiber optic hd video, data and ethernet multiplexer
Table of Contents

Advertisement

3.8 Optics

An SFP or SFP+ transceiver provides the optical interface for the 914-HDE. Many options exist including:
Singlemode or multimode fiber
Bi-directional 1310/1550 nm transceivers (L1 and M1 versions)
Bi-directional 1270/1330 nm transceivers (H1 version)
CWDM wavelengths
Higher or lower optical budgets
Due to the high data rates, singlemode fiber is recommended. Multimode fiber is only suitable for very short
links (< 300m). Typical link budgets for single mode fiber are 20dB for bi-directional single fiber or 24dB for dual
fiber CWDM. Focal Technologies has compatible CWDM modules that can be mounted and stacked with 914-
HDE systems.
Contact the factory for specific part numbers.

3.8.1 Flux Budget Calculation

When specifying an optical system, it is important to analyze system losses and fiber link distances in order to
calculate the required optical configuration. The following table shows a sample flux budget calculation for a
system with multiple ST bushings, a 10km singlemode fiber link and a FORJ. Actual losses can vary widely
from this, each system flux budget calculation must use data based on actual parts in use.
Component
Typical Output Power
Connector
Connector
FORJ
Connector
Connector
Cable (for 10 km length)
Connector
Connector
Total Losses
Received Power
Dispersion Penalty
Required Receive Sensitivity
Typical Receive Sensitivity
Available Margin
Notes:
Fiber Loss
Connector (ST/PC)
FORJ Loss (Max.)

3.8.2 Optical Safety

All lasers used in the 914-HDE system are Class I laser devices per IEC-60825 unless otherwise specified in
installation or configuration drawing. No special control measures or warning labels are required, although any
needless exposure of the eye should be avoided as a matter of good practice, and fibers should never be
viewed with magnifying instruments, e.g. fiber scopes, while optical power is present. Note that the optical
wavelengths are in the infrared range, so not visible, but magnifying instruments can still cause damaging levels
to the eye.
Focal Technologies Corporation
A Moog Inc. Company

Table 8: Sample Flux Budget Calculation

Uplink (1310 nm)
-1.0
-0.3
-0.3
-4.0
-0.3
-0.3
-4.0
-0.3
-0.3
-9.8
-10.8
-1.0
-11.8
-21.0
9.2
0.4 dB/km @ 1310 nm; 0.3 dB/km @1550 nm
0.3 dB/conn
4.0 dB
Model 914-HDE User Manual
Downlink (1550 nm)
-1.0
-0.3
-0.3
-3.0
-0.3
-0.3
-3.0
-0.3
-0.3
-8.8
-9.8
-1.0
-10.8
-21.0
10.2
Document Number: 914-0601-00 Rev. 4.0
Unit
dBm
dB
dB
dB
dB
dB
dB
dB
dB
dB
dBm
dB
dBm
dBm
dB
3-11

Hide quick links:

Advertisement