Chapter 1 Maintenance
The server module TeDoLi terminates in about 8 minutes from the start of execution. Enter "list" again
and check that Status of server modules is PASS.
MNG PC> list
Module List
+----------------+----------+----------+----------+
CSC
CPU Board1
CPU Board2
CPU Board3
:
CPU Board43
CPU Board44
+----------------+----------+----------+----------+
CSC : 1 CPU : 43 + MNG PC
PASS: 0 PASS: 43
FAIL: 0 FAIL: 0
MNG PC>
TP (Diagnosis program) of CSC modules is infinitely executed out of synchronization with TeDoLi.
Enter "stop 0" to stop it.
MNG PC> stop 0
MNG PC>
4.
If you find "Fail" in Status in step 3, specify the module with ' list "server module number" ' and check
the detail.
(Example: When you find the server module 23 to be Fail, enter "list 23".)
34
Important
TeDoLi startup request may be cancelled when BIOS setup is reset due to the
change of settings. If Type of CPU Board is not"TeDoLi", shut down the
server and run the TeDoLi startup command again. Check that the shutdown
process is complete by using the "list" command.
MNG PC> shutdown -f all
MNG PC> shutdown -f all
MNG PC> list
MNG PC> list
MNG PC> start tedoli all
MNG PC> start tedoli all
Power
Type
ON
TP
ON
MNG PC
ON
TeDoLi
ON
TeDoLi
ON
TeDoLi
ON
TeDoLi
Scalable Modular Server DX2000 Maintenance Guide
Status
Run
PASS
PASS
PASS
PASS
6. System Diagnostic Tool