14.4.2
Horizontal Airflow
Automatic horizontal airflow direction can be set using remote control; the vane swings left and right within the
angles as stated below. For heating mode operation, the angle of the vane depends on the indoor heat
exchanger temperature as Figure 1 below. It does not swing during fan motor stop.
Heating, with heat exchanger temperature
Cooling and soft dry
Manual horizontal airflow direction can be set using remote control; the angles of the vane are as stated below
and the positions of the vane are as Figure 2 above.
Operation
Automatic
Cooling, Heating,
Manual
Ventilation, Dry
operation
Wind direction position image
128°
Step 4
Step 5
Operation Mode
Swing
[X_HNADS_LR_CNML]
Closed
Position
Reference point
Step 1
Step 2
Closed
Position
Figure 2
A
B
1
2
90°
65°
66
128°
Step 3
Step 4
Step 5
Vane Angle (°)
65 ~115
90
65 ~115
Left and Right Vane
3
4
(Wind direction 2 to 5)
77.5°
102.5°
28°
5
115°