Therma-Stor Ultra Aire XT105H Owner's Manual

Therma-Stor Ultra Aire XT105H Owner's Manual

Hide thumbs Also See for Ultra Aire XT105H:

Advertisement

HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER
XT105H
Dehumidification
The highly efficient Ultra-Aire XT whole house ventilating
dehumidifier utilizes refrigeration to cool the incoming air stream
below its dew point. This cooled and drier air is used to pre-cool
the incoming air stream resulting in a significant increase in overall
efficiency. After the pre-cooling stage, the processed air is reheated
by passing through the condenser coil. The heat removed by the
evaporator coil is returned to the air stream, resulting in an overall
temperature increase of the air leaving the unit.
The Ultra-Aire XT's are controlled by 24 volt remote wired controls.
A variety of controls are available for various applications.
P/N 4032240 (XT105H)
P/N 4031070 (XT155H)
P/N 4031560 (XT205H) • Serial No.________________________ Install Date:___________
Sold by:
XT155H
Fresh Air Ventilation
Optional fresh outdoor air may be ducted to the unit via a six inch
round duct. This provides fresh air to dilute pollutants and replenish
oxygen content in the building. The amount of fresh air ventilation
can be regulated by a variety of dampers and controls.
Air Filtration
The Ultra-Aire XT includes air filtration to improve indoor air quality.
A MERV-11 media filter is standard. An optional external
filter box with a MERV-14 deep pleated 95% media filter is
available for optimum air filtration and to reduce potentially
harmful airborne particles.
4201 Lien Rd Madison, WI 53704
TOLL-FREE 1-800-533-7533
XT205H
PATENTS:
D570,988
8,069,681
www.thermastor.com
sales@thermastor.com
© 2007 Therma-Stor LLC • Manual P/N TS-693, 02/12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ultra Aire XT105H and is the answer not in the manual?

Questions and answers

Summary of Contents for Therma-Stor Ultra Aire XT105H

  • Page 1 P/N 4032240 (XT105H) P/N 4031070 (XT155H) P/N 4031560 (XT205H) • Serial No.________________________ Install Date:___________ Sold by: 4201 Lien Rd Madison, WI 53704 TOLL-FREE 1-800-533-7533 www.thermastor.com sales@thermastor.com • • • © 2007 Therma-Stor LLC • Manual P/N TS-693, 02/12...
  • Page 2 Ultra-Aire XT105H, XT155H, and XT205H Installer’s & Owner’s Manual...
  • Page 3 Ultra-Aire XT105H, XT155H, and XT205H Installer’s & Owner’s Manual...
  • Page 4: Duct Connections

    Unit: 4032240 XT105H 4031070 XT155H 4031560 XT205H Blower: 257 CFM @ 0.0" WG 391 CFM @ 0.0" WG 526 CFM @ 0.0" WG 206 CFM @ 0.2" WG 363 CFM @ 0.2" WG 495 CFM @ 0.2" WG (Tested with duct collars on) 146 CFM @ 0.4"...
  • Page 5 FOR HVAC INSTALLER ONLY Ultra-Aire XT105H, XT155H, and XT205H Installer’s & Owner’s Manual...
  • Page 6 Ultra-Aire XT105H, XT155H, and XT205H Installer’s & Owner’s Manual...
  • Page 7 Ultra-Aire Dehumidifier Ultra-Aire XT105H, XT155H, and XT205H Installer’s & Owner’s Manual...
  • Page 8 Ultra-Aire Dehumidifier Ultra-Aire Dehumidifier OPTIONAL DAMPER (P/N 4028539; with remote: P/N 4028407) DMP COMP FAN Internal Connections • • • Ultra-Aire XT105H, XT155H, and XT205H Installer’s & Owner’s Manual...
  • Page 9 WARNING: Allowing yellow wire to contact red or white wire will destroy the transformer. Dehumidifier on : Connect yellow and blue wires. Fan only on : Connect yellow and green (or brown) wires. Accessory power : 24volt AC power supply available for HVAC accessories between yellow and white(and/or red) wire.
  • Page 10 DEH 3000/DEH 3000R DEH 3000/DEH 3000R Part No. 4028539 Part No. 4028407 Ultra-Aire XT105H, XT155H, and XT205H Installer’s & Owner’s Manual...
  • Page 11: Maintenance

    6. Maintenance 7.2 Technical Description 6.1 Standard Air Filter The Ultra-Aire XT uses a refrigeration system similar to an air conditioner's to remove heat and moisture from incoming air, and The Ultra-Aire XT is equipped with a pleated cloth air filter. This add heat to the air that is discharged (See Figure 15).
  • Page 12: Refrigerant Charging

    Compressor is not running. Dehumidification is being called Unit Test to determine problem: for. No fan call. 1. Detach field control wiring connections from main unit. 1. Defective compressor run capacitor (Sec. 7.6). 2. Connect the yellow and green pigtails from the main unit 2.
  • Page 13: A Checking Compressor Motor Circuits

    7.6A Checking Compressor Motor Circuits The following procedure is effective only if the system is monitored after replacing the compressor to insure that the clean up was Perform the following tests if the impeller fan runs but the complete. compressor does not with the fan switch and ventilation timer OFF and the humidity control ON.
  • Page 14: Remote Controls

    7.6C Replacing a Compressor, Nonburn Out 7.9 Electric Ventilation Damper Remove the refrigerant from the system. Replace the compressor The damper will open when the ventilation is called for, allowing and liquid line filter/drier. Charge the system to 50 PSIG and check fresh air into the structure through the fresh air inlet duct.
  • Page 15 Electric Schematics of the Ultra-Aire XT UNIT E-BOX BLK 1 BLU 2 MAKE SURE WIRE IS GRN 9 1413 CAPPED IF DAMPER N.O. IS NOT USED RED 6 WHT 6 GRN 5 GRN 5 WHT 4 WHT 4 WHT 4 RED 1 RED 1 YEL 6...
  • Page 16 Item Part No Description Item Part No Description 4021475 Air Filter 16x20x2" MERV-11 4032196 (XT105) Impeller 4026221 Foot, Leveling, 5/16-18 4026657 (XT155) Impeller 4031085 Condenser Coil 4031089 (XT205) Impeller 4031086 (XT105 & XT155) Evaporator Coil 4031917 (XT105) Compressor Capacitor, 4031086-01 1 (XT205) E-coat Evaporator Coil 35 MFD, 370V, Oil 4029510...
  • Page 17 PART NO. QTY. DESCRIPTION 4024375 Check Damper, 10" Diameter 4028614 Condensate Pump Kit, External 4023672 Duct Damper, 6" Diameter, Electrically Actuated 4025560 Switch, Black, SPDT, On/Off 4024369 Merv 11 Standard Filter 20" x 16 "x 2" 4032221 Filter Box (Needed when MERV 14 filter is used) 4028539 DEH 3000 Digital Controller 4028407...
  • Page 18 Door Install Insert tab on the bottom of the door, in between the foam installation and the metal side. Push down on the plastic door latch and swing door shut. Once the door is shut release the door latch. Collar Install Remove the 2 round ducts, oval duct seal and small bag of mounting hardware from inside the rectangle opening.
  • Page 19: Limited Warranty

    Miscellaneous. If any term or condition of this Limited Warranty of nature or other causes not arising out of defects in Therma-Stor’s workmanship or material. If a Product or Component is replaced...