Therma-Stor Ultra-Aire XT150H Installer's & Owner's Manual

Therma-stor llc. owner's manual dehumidifier xt150h
Table of Contents

Advertisement

Quick Links

INSTALLER'S & OWNER'S MANUAL
HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER
Dehumidification
The highly efficient Ultra-Aire XT150H dehumidifier utilizes
refrigeration to cool the incoming air stream below its dew point.
This cooled and drier air is used to pre-cool the incoming air stream
resulting in a significant increase in overall efficiency. After the pre-
cooling stage, the processed air is reheated by passing through the
condenser coil. The heat removed by the evaporator coil is returned
to the air stream, resulting in an overall temperature increase of the
air leaving the unit.
The Ultra-Aire XT150H is controlled by 24 volt remote wired controls.
A variety of controls are available suitable to various applications.
P/N 4026480 • Serial No.________________________ Install Date:___________
Sold by:
Fresh Air Ventilation
Optional fresh outdoor air may be ducted to the unit via a six inch
round duct. This provides fresh air to dilute pollutants and maintain
high oxygen content in the air. The amount of fresh air ventilation
can be regulated by a variety of dampers and controls.
Air Filtration
The Ultra-Aire XT150H includes air filtration to improve indoor air
quality. A MERV-11 media filter is standard. An optional external
MERV-14 deep pleated 95% media filter is available for optimum air
filtration and to reduce potentially harmful airborne particles. If the
optional filter is chosen, a standard filter operates as a prefilter.
P.O. Box 8680 Madison, WI 53708
TOLL-FREE 1-800-533-7533
www.thermastor.com
sales@thermastor.com
© 2007 Therma-Stor LLC • Manual P/N TS-372, 8/07

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ultra-Aire XT150H and is the answer not in the manual?

Questions and answers

Summary of Contents for Therma-Stor Ultra-Aire XT150H

  • Page 1 The Ultra-Aire XT150H is controlled by 24 volt remote wired controls. A variety of controls are available suitable to various applications. P/N 4026480 • Serial No.________________________ Install Date:___________...
  • Page 2: Table Of Contents

    7.10 Condensate Pump Kit ... 15 Electrical Schematic ... 16 Pictorial Electrical Diagram ... 17 Service Parts List ... 18 Optional Parts List ... 19 Door and Collar Assembly ... 20 Warranty ... 21 Ultra-Aire XT150H Installer’s & Owner’s Manual...
  • Page 3: Safety Precautions

    Proper adherence to these instructions is essential to obtain maximum benefit from your Ultra-Aire XT150H indoor air quality system. READ AND SAVE THESE INSTRUCTIONS • The device is designed to be installed INDOORS IN A SPACE THAT IS PROTECTED FROM RAIN AND FLOODING.
  • Page 4: Intended Application

    24" location for the fresh air ducting. A 6" round insulated duct will have to be installed on the Ultra-Aire XT150H and run to the outside 164 lbs of the structure to bring in fresh air. Use an 8" insulated round duct for lengths of more than 50 feet or if more than 100 CFM is needed.
  • Page 5: Condensate Removal

    All flexible ducting connected to the Ultra-Aire XT150H should be UL listed. The inlet of the Ultra-Aire XT150H is the 10" diameter hole in the filter enclosure of the unit. A 10" round collar is supplied with the unit to attach to round duct.
  • Page 6: C Ducting For Fresh Air

    Existing Forced Air HVAC System It is recommended that a new, separate return duct be installed for the Ultra-Aire XT150H from a central area of the house. If this is not possible, and if the existing system has multiple returns, select one to disconnect from the existing forced air system and use it for the dedicated Ultra-Aire XT150H return.
  • Page 7: E Installation In A Attic

    Refer to section 3.4B for branch duct sizing. Connect an insulated duct from outside to the 6" collar of the Ultra-Aire XT150H if you wish to provide fresh air ventilation. 3.5 Quiet Installation Consider compression vibration and airflow noise during installation.
  • Page 8: Ventilation Or Damper

    The ventilation timer controls the fan and the motorized fresh air damper. When the ventilation timer is activated, the Ultra- Aire XT150H will circulate the indoor air, and bring in fresh air from outside. The ventilation timer should be set for the required ventilation of the residence.
  • Page 9: A Setting The Time

    If the timer fails to operate or operates erratically, check that the control panel receives 24Vac from the Ultra-Aire XT150H. If 24Vac is present at the control panel, reset the timer by pressing the reset button at the bottom center of the timer face.
  • Page 10: Attention Installer

    Do not direct connect the white lead on the unit to the violet lead on the ventilation control or damage to the transformer will result. Ultra-Aire XT150H Installer’s & Owner’s Manual...
  • Page 11: Optional Dehumidifier & Ventilation System Controller

    Programmable Ventilation Timer Large, easy-to-read backlit LCD display Easy interaction with air handler fan (Interlock/Lockout) High Temperature Cut-Out Dryout Cycle Timer Auto Reboot Remote Sensor (DEH 3000R Only) To order call Therma-Stor at ± 1-800-533-7533 Ultra-Aire XT150H Installer’s & Owner’s Manual...
  • Page 12: Maintenance

    To access the air filter, remove the filter access panel from the end of the Ultra-Aire XT150H. The filter should be readily visible and can be removed by pulling them straight out of the Ultra-Aire XT150H.
  • Page 13: Refrigerant Charging

    1. Unplug the power cord. 2. Remove the cabinet access panel. 3. Remove the screw attaching the impeller fan support bracket to the base. 4. Disconnect the impeller fan leads inside the electric box. Ultra-Aire XT150H Installer’s & Owner’s Manual...
  • Page 14: Compressor/Capacitor Replacement

    Thoroughly flush the accumulator with refrigerant to remove all trapped sludge and to prevent the oil hole from becoming plugged. A standing burn out does not require a suction line filter/drier. Ultra-Aire XT150H Installer’s & Owner’s Manual...
  • Page 15: C Replacing Compressor-Nonburn Out

    The ventilation timer controls the impeller fan and the motorized fresh air damper. When the ventilation timer is activated, the Ultra-Aire XT150H will circulate the indoor air, and bring in fresh air from outside. The ventilation timer should be set for the required ventilation of the residence.
  • Page 16: Electrical Schematic

    This switch should be installed in series with the field wire that connects the blue (#5) lead from the Ultra-Aire XT150H to the blue (#5) lead on the control panel. If the pump fails, this switch opens the compressor control circuit and stops water production before the reservoir overflows.
  • Page 17: Pictorial Electrical Diagram

    FOR HVAC INSTALLER ONLY Pictorial Electrical Diagrams of Ultra-Aire XT150H Ultra-Aire XT150H Installer’s & Owner’s Manual...
  • Page 18: Service Parts List

    45mFd CAPACITOR - COMPRESSOR TRANSFORMER RELAY/COMPRESSOR 15mFd CAPACITOR - IMPELLER COLLAR 10 INCH COLLAR OVAL 10 INCH COLLAR W/ DAMPER 6 INCH (NOT SHOWN) LEVELING FOOT DEFROST THERMOSTAT (NOT SHOWN) DEFROST THERMOSTAT CLIP (NOT SHOWN) WIRING DIAGRAM Ultra-Aire XT150H Installer’s & Owner’s Manual...
  • Page 19: Optional Parts List

    Instructions, Ventilation Timer & Humidity (not shown) Switch, Black, SPDT, On/Off Timer, 7-Day, 24 Vac, Programmable Merv 11 Standard Filter 20" x 16 "x 2" Filter Box DEH 3000 Digital Controller (not shown) DEH 3000R Digital Controller (not shown) Ultra-Aire XT150H Installer’s & Owner’s Manual...
  • Page 20: Door And Collar Assembly

    Adhere seals onto the back of each duct and mount the ducts to the front of the dehumidifier using screws provided. Ultra-Aire XT150H Installer’s & Owner’s Manual Collars and hardware are located here.
  • Page 21: Warranty

    Limited Warranty. Therma-Stor, LLC (“Therma-Stor”) warrants as follows: (i) the Ultra-Aire XT150H dehumidifier (“Product”) will be free of material defects in workmanship or materials for a period of one (1) year (“One-Year Warranty”) following the date of initial purchase of such Product by an original customer purchasing from Therma- Stor or an authorized reseller (“Customer”);...
  • Page 22 Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of Therma-Stor LLC. © 2007 Therma-Stor LLC. All rights reserved. Ultra-Aire XT150H Installer’s & Owner’s Manual...

Table of Contents