●5.4 Motor and control parameters
·Please refer to the name plate setting of motors.
Code
Name
Detailed instruction of parameters
P02 Group Motor
Rated power
of
P02.01
asynchronous
motor
Rated
frequency of
P02.02
asynchronous
Set the parameter of the controlled asynchronous motor.
motor
In order to ensure the controlling performance, set the
Rated speed
P2.01~P2.05 according to the name plate of the
of
asynchronous motor.
P02.03
asynchronous
In order to ensure the controlling performance, please
motor
configure the motor according to the standard principles, if
the gap between the motor and the standard one is huge,
Rated voltage
the features of the inverter will decrease.
of
P02.04
asynchronous
motor
Rated current
of
P02.05
asynchronous
motor
Stator resistor
of
P02.06
asynchronous
motor
Rotor resistor
of
P02.07
asynchronous
motor
Leakage
These parameters are basic parameters controlled by
inductance of
P02.08
vectors which directly impact the features.
asynchronous
Note: Users cannot modify the parameters freely.
motor
Mutual
inductance of
P02.09
asynchronous
motor
Non-load
current of
P02.10
asynchronous
motor
0:No protection
Motor
1: Common motor (with low speed compensation).
P02.26
overload
2: Frequency conversion motor (without low speed
protection
compensation)
Motor
overload
Times of motor overload M = Iout/(In*K)
P02.27
protection
20.0%~120.0%
coefficient
P04 Group
Motor V/F
0:Straight line V/F curve;
P04.00
curve setting
1:Multi-dots V/F curve
P04.01
Torque boost
Torque boost
P04.02
close
The setting range of P04.01:0.0%:
Motor V/F
(automatic) 0.1%~10.0%
P04.03
frequency
The setting range of P04.02: 0.0%~50.0%
point 1
Note: V1<V2<V3, f1<f2<f3. Too high low frequency
Motor V/F
voltage will heat the motor excessively or damage. The
P04.04
voltage
inverter may occur in the overcurrent speed or overcurrent
point 1
protection.
Motor V/F
P04.05
frequency
The setting range of P04.03: 0.00Hz~P04.05
point 2
The setting range of P04.04, P04.06 and P04.08 :
Motor V/F
0.0%~110.0%
P04.06
voltage point 2
The setting range of P04.05: P04.03~ P04.07
The setting range of P04.07: P04.05~P02.02 (the rated
Motor V/F
frequency of motor)
P04.07
frequency
point 3
Motor V/F
P04.08
voltage point 3
△ f=f
-n*p/60
b
Of which, f
is the rated frequency of the motor, its function
b
code is P02.02; n is the rated rotating speed of the motor
Motor V/F slip
and its function code is P02.03; p is the pole pair of the
P04.09
compensation
motor. 100.0% corresponds to the rated slip frequency △ f.
gain
Note: no torque compensation for single-phase 220V
inverters
Setting range: 0.0~200.0%
Low frequency
P04.10
vibration
control factor
High
The setting range of P04.10: 0~100
frequency
The setting range of P04.11: 0~100
P04.11
vibration
The setting range of P04.12: 0.00Hz~P00.03 (the Max.
control factor
frequency)
Vibration
P04.12
control
threshold
Energy-saving
0: No operation
P04.26
operation
1: Automatic energy-saving
P05 Group Input terminals
S1 terminal
0: No function
P05.01
function
1: Forward rotation operation
selection
2: Reverse rotation operation
3: 3-wire control operation
S2 terminal
4: Forward rotation jogging
P05.02
function
5: Reverse rotation jogging
selection
6: Coast to stop
S3 terminal
7: Fault reset
P05.03
function
8: Operation pause
selection
9: External fault input
S4 terminal
10: Increasing frequency setting (UP)
P05.04
function
11: Decreasing frequency setting (DOWN)
selection
12: Cancel the frequency change setting
S5 terminal
13: Shift between A setting and B setting
P05.05
function
14: Shift between combination setting and A setting
Quick Start Guide of CV10- ControlVIT Series
 
Default
value
Depends
on model
50.00Hz
Depends
on model
Depends
on model
Depends
on model
Depends
on model
Depends
on model
Depends
on model
Depends
on model
Depends
on model
2
100.0%
SVPWM control
0
0.0%
20.0%
0.00Hz
00.0%
00.00Hz
00.0%
00.00Hz
00.0%
0%
10
10
30.00 Hz
0
1
4
7
0
0
Code
Name
selection
15: Shift between combination setting and B setting
16: Multi-step speed terminal 1
17: Multi-step speed terminal 2
Modify
18: Multi-step speed terminal 3
19: Multi- step speed terminal 4
20: Multi- step speed pause
21: ACC/DEC time option 1
25: PID control pause
26: Traverse Pause (stop at the current frequency)
27: Traverse reset (return to the center frequency)
28: Counter reset
30: ACC/DEC prohibition
31: Counter trigger
33: Cancel the frequency change setting temporarily
34: DC brake
36: Shift the command to the keypad
37: Shift the command to the terminals
38: Shift the command to the communication
Lower limit of
AI1 is set by the analog potentiometer
P05. 32
AI1
0.00V~P05.34
Corresponding
setting of the
P05.33
-100.0%~100.0%
lower limit of
AI1
Upper limit of
P05.34
P05.32~10.00V
AI1
Corresponding
setting of
P05.35
-100.0%~100.0%
the upper limit
of AI1
AI1 input filter
P05.36
0.000s~10.000s
time
Lower limit of
AI2 is set by control terminal
P05.37
AI2
0.00V~P05.39
Corresponding
setting of the
P05.38
-100.0%~100.0%
lower limit of
AI2
Upper limit of
P05.39
P05.37~10.00V
AI2
Corresponding
setting of
P05.40
-100.0%~100.0%
the upper limit
of AI2
AI2 input filter
P05.41
0.000s~10.000s
time
0: Invalid
Y output
P06.01
1: On operation
selection
2: Forward rotation operation
3: Reverse rotation operation
4: Jogging operation
5: The inverter fault
6: Frequency degree test FDT1
7: Frequency degree test FDT2
8: Frequency arrival
9: Zero speed running
10: Upper limit frequency arrival
Relay RO
11: Lower limit frequency arrival
P06.03
output
12: Ready for operation
14: Overload pre-alarm
selection
15: Underload pre-alarm
16: Completion of simple PLC stage
17: Completion of simple PLC cycle
18: Setting count value arrival
19: Defined count value arrival
20: External fault valid
22: Running time arrival
23: MODBUS communication virtual terminals output
When the current bit is set to 0, input terminal is positive.
When the current bit is set to 1, input terminal is negative.
Polarity of
P06.05
output
terminals
Setting range: 00~0F
Y switching on
P06.06
0.000~50.000s
delay time
Y switching off
P06.07
0.000~50.000s
delay time
RO switching
P06.10
on delay time
0.000~50.000s
RO switching
P06.11
off delay time
0:Running frequency
1:Set frequency
2:Ramp reference frequency
3:Running rotation speed
4:Output current (relative to the rated current of the
inverter)
5:Output current(relative to the rated current of the motor)
P06.14
AO output
6:Output voltage
7:Output power
8:Set torque value
9:Output torque
10:Analog AI1 input value
11:Analog AI2 input value
14:MODBUS communication set value 1
15:MODBUS communication set value 2
Lower limit of
P06.17
AO output
Corresponding
When the analog output is current output, 1mA equals to
P06.18
AO output to
0.5V.
the lower limit
In different cases, the corresponding analog output of
Upper limit of
100% of the output value is different. Please refer to each
P06.19
AO output
application for detailed information.
Setting range of P06.18: 0.00V~10.00V
The
Setting range of P06.19: P06.17~100.0%
corresponding
P06.20
Setting range of P06.20: 0.00V~10.00V
AO output to
Setting range of P06.21: 0.000s~10.000s
the upper limit
AO output
P06.21
filter time
 
3 / 5
Detailed instruction of parameters
P06 Group
Output terminals
BIT3
BIT2 
BIT1 
Reserved
RO1
Reserved
Default
Modify
value
0.00V
0.0%
10.00V
100.0%
0.100s
0.00V
0.0%
10.00V
100.0%
0.100s
0
1
 
BIT0 
00
Y
0.000s
0.000s
0.000s
0.000s
0
0.0%
 
0.00V
100.0%
 
10.00V
0.000s
EL086A01