DIMENSIONS AND WEIGHT
The dimensions and weight of the base station fitted within the standard enclosure are:
Width
Height
Depth
Weight
The dimensions and weight of the rack mounted base station are:
Width
Height
Depth
Weight
INPUT SUPPLIES
The base station can operate from an ac mains supply, or an external dc input supply. When both
supplies are connected, the dc supply acts as a backup supply should the mains fail.
ac Supply
The base station requires the following ac input supply:
Input voltage
Maximum current
dc Supply
The base station requires the following dc input supply:
Input voltage
Maximum current
OPTIONAL INTERNAL BATTERY
An optional internal battery can be fitted to power the base station when external supplies fail. The
battery provides:
Voltage
Operating time
T6M Base Station User Guide
Page 14
446 mm.
176 mm.
400 mm.
9.5 kg without battery option fitted.
11.5 kg with battery option fitted.
483 mm.
89 mm (2U).
423 mm.
9 kg without battery option fitted.
11 kg with battery option fitted.
Between 98 and 254 V ac at either 50 or 60 Hz.
2 A.
Between 12 and 15.5 V. For maximum transmitter output
power, the dc input must be between 14 and 15.5 V.
9 A.
12 V dc.
The battery provides at least two hours of operation
when the duty cycle does not exceed 10% (measured at
a working temperature of 25° C). The transmitter output
power is reduced by up to 3 dB during battery operation.