Viewing Results Stored In Memory - Fluke 1550 User Manual

Megohmmeter
Hide thumbs Also See for 1550:
Table of Contents

Advertisement

1550
Users Manual

Viewing Results Stored in Memory

The Meter can store 99 sets of test data, including:
⇒ Limit – timer on or off
⇒ Timer reading at termination of test
⇒ Capacitance
⇒ Ramp on or off
⇒ Selected test voltage and measured test voltage
⇒ Test current
⇒ Reason for ending the test.
To view stored test data:
O
1.
Press
to turn on the Meter.
G
to select the RESULTS function.
2.
Press
When a voltage is present at the terminals, that voltage is always shown on
the top-center of the display, regardless of whether that voltage is sourced
by the Meter or is from the circuit under test.
00k
0
e
3.
Press
to access the test results storage locations. The memory
location appears on the bottom-right of the display.
V
d
4.
Press
or
R
5.
Press
to view the stored test data for a specific test. Test data appears
on the alphanumeric text display and on the LCD.
e
6.
Press
to return the Meter to Ready mode.
18
V
00M
G
0M
0G
M
G
k
to scroll through the different stored tests.
5000V 2500V
000V
500V
00G
T
T
M
Stored Test
Results
Voltage at
Terminals
of Tester
ADB06F.EPS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents