SCANNER
6.2.7 AUTO IMAGE DENSITY CORRECTION
Auto Image Density Correction corrects
the background density.
Contact Image Sensor (Center)
70 mm
70 mm
The CIS reads the surface of the white
5 mm
platen roller and uses this reading (white
point =0) as a reference point for density
correction.
Texture detection Area
Next, the CIS starts 5 mm from the
leading edge and reads 70 mm to the left
and right of center to perform image
density correction line by line.
B010D514.WMF
6.2.8 ORIGINAL EXIT SWITCHING MECHANISM
[A]
[B]
B010D603.WMF
Original Junction Gate
Original Junction Gate
Solenoid ON
Solenoid OFF
An operation panel setting determines whether the original exits the upper exit [A]
or rear exit [B]. When the upper exit is selected, the solenoid stays off, and the
original exits at the upper exit. This is the default setting.
When the rear exit key is selected, the solenoid switches on when the registration
sensor detects the leading edge of the original, and the original exits at the rear [B].
SM
6-9
B010