Communications Subcommand - Omron V670-CF01 User Manual

V670 series electromagnetic inductive rfid system
Table of Contents

Advertisement

SECTION 4
Commands

Communications Subcommand

The communications subcommand is used in combination with communications commands. No
communications processing is performed with Tags when the communications subcommand is used alone.
Command Processing Abort (AA)
Aborts processing of a command being executed and returns to the command standby status. Com-
mand Processing Abort can be executed during the processing of any command.
Command
Command
Proc-
code "AA"
ess
desig-
nation
2
Process designation
Antenna designation
Response
Command
code "AA"
2
When command processing has been aborted after a Tag is detected, the status flag will be "2".
Example: Aborting Command Processing during Execution
Send data:
Receive data: AA0000*[CR]
Electromagnetic Inductive RFID System
52
User's Manual
Antenna
desig-
CR
nation
2
1
1
Always "0".
Always "1".
End code
Retry
Status
flag
flag
CR
2
2
1
1
AA01*[CR]

Advertisement