Connecting The Connection Cord - Samsung ACN016NDEHA Installation Manual

Table of Contents

Advertisement

Connecting the connection cord

If using a multi system, refer to the manual supplied with the outdoor unit.
the electric connections.
The indoor unit is powered by the outdoor unit by means of a H07 RN-F connection cable (or a more power model),
with insulation in synthetic rubber and jacket in polychloroprene(neoprene), in accordance with the requirements of standard EN 60335-2-40.
1. Remove the screw on the electrical component box and remove the cover plate.
2. Route the connection cord through the side of the indoor unit and connect the cable to terminals; refer to the figure below.
3. Route the other end of the cable to the outdoor unit through the ceiling & the hole on the wall.
4. Reassemble the electrical component box cover, carefully tightening the screw.
Wiring diagram
1 phase
L
N
Indoor Unit
1(L) 2(N)
L
N
Cable tie
Indoor Power
Main power cable
Cable clamp
Between Indoor and Outdoor Connection cable Specifications(Common in use)
Indoor Power supply
Power Supply
Terminal Block SPEC (Indoor)
11
13
F4
F3
V2
V1
F2
F1
F3
F4
V1
V2
Wired Remote
Controller(Optional)
Communication cable
Communication Cable
Indoor Power cable
0.75~1.5mm²,3wires
0.75~1.5mm²,2wires
cable of FROHH2R type.
7.5
9.0
M3.5
8.0~10.0
M4
12.0~15.0
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents