Connecting The Connection Cord - Samsung NS 1DXEA Series Installation Manual

Table of Contents

Advertisement

AA

Connecting the connection cord

Connecting the connection cord
• Always remember to connect the refrigerant pipes before performing the electric connections.
When disconnecting the system, always disconnect the electric cables before disconnecting the refrigerant pipes.
• Always remember to connect the air conditioner to the grounding system before performing
the electric connections.
The indoor unit is powered by the outdoor unit by means of a H07RN-F/H05RN-F connection cable (or a more power model),
with insulation in synthetic rubber and jacket in polychloroprene(neoprene), in accordance with the requirements of standard EN 60335-2-40.
1. Remove the screw on the electrical component box and remove the cover plate.
2. Route the connection cord through the side of the indoor unit and connect the cable to terminals; refer to the figure below.
3. Route the other end of the cable to the outdoor unit through the ceiling & the hole on the wall.
4. Reassemble the electrical component box cover, carefully tightening the screw.
Wiring diagram
1 phase
2(N)
1(L)
Indoor Unit
Outdoor Unit
1(L) 2(N)
L
Indoor Power
Main power cable
Cable clamp
14
CAC 유럽향 1way_IM_34507A-05_EN.indd 14
N
Cable tie
Communication cable
2016-08-02 오후 4:08:11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ac fb1deh series

Table of Contents