Page 1
Air conditioner Installation manual AC***TX4***, AC***TXM***, AC***TXQ*** DB68-08577A-04...
Page 2
Contents Safety Information Installation Procedure Extra procedures Appendix Correct Disposal of This Product (Waste Electrical & Electronic Equipment) (Applicable in countries with separate collection systems) 2 English...
Page 4
Safety Information Installing the unit Power supply line, fuse or circuit breaker WARNING WARNING IMPORTANT: When installing the unit, always • remember to connect first the refrigerant tubes, then the electrical lines. • • • • • • • • •...
Page 5
Indoor Unit Remote control sensor 1.5 m or more 1.5 m or more 300 mm Outdoor Unit Protection wall Sea breeze Stereo Computer etc 200 mm Outdoor Unit Air Guide Duct (This product is not provided by Samsung) • • English...
Page 6
Installation Procedure CAUTION C Type • • • D Type • • – – Minimum clearances for the outdoor unit • When installing 1 outdoor unit (Unit: mm) Outdoor unit dimensions (Unit: mm) A Type 2000 300 or 600 or or more more more...
Page 7
When installing more than 1 outdoor unit CAUTION (Unit: mm) • 1500 3000 3000 or more or more or more or more or more WARNING • or more or more [Bar type louver] [Rain resistance louver] or more or more •...
Page 8
Installation Procedure CAUTION Wire rope • Plate protection cloth • • Step 2 Fixing the outdoor unit in place • • Optional: Fixing the outdoor unit to a wall with a rack Designed to cut off residual vibration from outdoor unit to (Unit : mm) AC018/024TX**** rack.
Page 9
Step 3 Connecting the power cables, Air conditioning system examples communication cable, and controllers Communication cable Main power • Outdoor-to-indoor power cable cable MCCB Earthing • ELCB • Outdoor Unit Indoor Unit CAUTION • Communication cable Main power Outdoor-to-indoor power cable cable MCCB Earthing...
Page 10
Installation Procedure When using ELB for AC036/048/060TX**** Electrical Power supply component box AC036/048/060TX**C* (1-phase) MCCB 1(L) 2(N) Cable tie Outdoor-to- Main power Communication cable indoor power cable cable AC048/060TX**H* (3-phase) 1(L) 2(N) L1(R) L2(S) L3(T) The appearance of the unit may be different from the picture depending on the model.
Page 11
Main power terminal block specifications • • AC power Communication AC power Communication : M4 screw : M4 screw : M4 screw : M4 screw 1(L) 2(N) 1(L) 2(N) 10.1 10.1 16.3 11.4 11.4 • AC power Communication : M4 screw : M4 screw 1(L) 2(N)
Page 12
Installation Procedure Single phase Model Outdoor unit Input current (Amperes) Power supply Rated Voltage range Outdoor unit Indoor Indoor unit Outdoor unit Total unit Volts Min. Max. Cooling Heating AC018TN4FCH AC018TXQFCH AC018TN4PCH AC018TX4PCH AC018TNMPCH AC018TXMPCH AC018TN4LCC AC018TXQLCC AC018TN4PCC AC018TX4PCC AC018TNMPCC AC018TXMPCC AC024TN4FCH AC024TXQFCH...
Page 13
NOTE • Model Ssc[MVA] • • • • Silence mode controller wiring diagram • • Outdoor unit Outdoor unit CN001 ASSY Control out CN001 Non-voltage contact Non-voltage contact English...
Page 14
Installation Procedure Connecting the outdoor-to-indoor power cable and the communication cable Indoor unit : 360 CST (AC***TN4F**, AC***TN4L**, AC048TN4FCH/SU) • • Indoor Unit Indoor Unit Outdoor Unit Outdoor Unit 1(L) 2(N) 1(L) 2(N) Cable Cable clamp Cable tie Outdoor to indoor Communication Main power Outdoor to indoor...
Page 15
Indoor unit : 4way CST (AC***TN4P**) • • Indoor Unit Indoor Unit Outdoor Unit Outdoor Unit 1(L) 2(N) L 1(L) 2(N) L Cable tie Cable Communication Outdoor to indoor Main power Cable clamp cable power cable cable Communication Outdoor to indoor Main power cable power cable...
Page 16
Installation Procedure Indoor unit : DUCT (AC***TNMP**) • • Indoor Unit Indoor Unit F1 F2 F1 F2 Cable clamp Cable clamp Outdoor Unit Outdoor Unit 1(L) 2(N) 1(L) 2(N) Cable Cable tie Cable clamp Outdoor to indoor Main power cable Communication Outdoor to indoor Communication...
Page 17
Indoor unit : DUCT (AC***TNMP**) • • Indoor Unit Indoor Unit 1(L) 2(N) 1(L) 2(N) Cable clamp Cable clamp Cable tie Cable tie Outdoor Unit Outdoor Unit 1(L) 2(N) 1(L) 2(N) L1(R) L2(S) L3(T) Cable tie Cable tie Outdoor to indoor Main power cable Communication Outdoor to indoor...
Page 18
Installation Procedure Outdoor-to-indoor power terminal specifications • • Silver solder Nominal Nominal dimensions dimensions Standard Standard Standard Standard Allowance Allowance Allowance Min. Min. Max. Allowance Min. for cable for screw dimension dimension dimension dimension (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm²)
Page 19
Outdoor-to-indoor power and communication Step 4 Optional: Extending the power cables specifications cable • Indoor unit : 360 CST (AC***TN4F**, AC***TN4L**, AC048TN4FCH/SU) 4way CST (AC***TN4P**) Tools Spec Shape Indoor power supply Power supply Max/Min (V) Indoor power cable Communication cable •...
Page 21
Step 5 Connecting the refrigerant pipe CAUTION Items Maximum allowable length [m] Applicable outdoor unit models Pipe outlet Main pipe (L1) Max. height difference between outdoor and indoor units (h1) • indoor • outdoor • • • Outer diameter Minimum thickness Temper grade [mm] [mm]...
Page 22
Installation Procedure Step 7 Installing oil traps • • R 0.4 to 0.8 mm • Flare Pipe Pipe Flare diameter Radius of Outer diameter Flare dimension Depth (A) curvature • • Indoor Unit Oil trap (Install it at every 10 m) Outdoor Unit Uneven Damaged...
Page 23
Step 8 Connecting up and removing air in the circuit CAUTION CAUTION • • • AC018/024TX**** A(Gas) B(liquid) Vacuum pump • AC036/048/060TX**** Outdoor Unit A (Gas) B (Liquid) Outdoor Unit Vacuum Pump Outer Diameter (D) Torque (N m) A(Gas) B(liquid) English...
Page 24
Installation Procedure • AC018/024TX**** • • • AC018/024TX**** • • CAUTION • • AC036/048/060TX**** NOTE • • Step 9 Adding refrigerant (R-410A) • Calculating the quantity of refrigerant to add AC036/048/060TX**** Liquid side stop valve(service port) Indoor Unit Gas side stop valve(service port) Balance Outdoor Unit Vacuum...
Page 26
Installation Procedure Step 10 Performing the gas leak test Step 11 Connecting the drain hose to the outdoor unit LEAK TEST WITH NITROGEN (before opening valves) LEAK TEST WITH R-410A (after opening valves) • A(Gas) B(Liquid) 80 mm 13 mm •...
Page 27
• • Drain cap (3EA) Drain plug (1EA) • • Insulation Type (Heating/Cooling) • High Standard humidity Pipe size • Pipe Remarks [Less than (mm) [over 30°C, 30°C, 85%] 85%] EPDM, NBR (mm) Step 12 Insulating the refrigerant pipes • No gap –...
Page 28
Installation Procedure Step 13 Checking the earthing trial operation • • • • • NOTE • Carbon plastic Steel core Terminal M4 PVC-insulated To grounding screw green/yellow wire 50 cm Display 30 cm Key Push type Mode SEG 1 SEG 2SEG 3 •...
Page 30
Installation Procedure short Display contents SEG1 SEG2 SEG3 SEG4 Unit push Display contents SEG1 SEG2 SEG3 SEG4 After short push 1 After short K4 long push 2 push After short push 3 After short push 4 English...
Page 31
Option Input SEG1 SEG2 SEG3 SEG4 Function item unit Snow accumulation • prevention control – Step for Silence mode Type of Silence mode – – Not applicable • Not applicable Current restriction rate • • CAUTION • • Option Input SEG1 SEG2 SEG3 SEG4 Function item...
Page 32
Extra Procedures Pumping down refrigerant • WARNING • B(liquid) A(Gas) – Relocating the indoor and outdoor units Pumping down refrigerant NOTE • • A(Gas) B(Liquid) 32 English...
Page 33
Using the stop valve NOTE • Opening the stop valve • Tightening torque for charging port cap (Refer to the table) Closing the stop valve Charging Core R-22 : Thread of the screw - 7/16-20UNF R-410A : Thread of the screw - 1/2-20UNF Spindle CAUTION •...
Page 34
Appendix Troubleshooting Error Meaning Remarks Code 34 English...
Page 36
Appendix Packing and unpacking guide Indoor unit Cushion-top Packing case Indoor unit Cushion-bottom • • English...
Page 37
Indoor unit Cushion-top Packing case Indoor unit Cushion-bottom • • English...
Page 38
Appendix Indoor unit Cushion-top Packing case Indoor unit Cushion-bottom Packing case-bottom • • English...
Page 39
Indoor unit Cushion-top Packing case Indoor unit Cushion-bottom • • English...
Page 40
Appendix Indoor unit Cushion-top Indoor Unit Packing case Cushion side Cushion bottom • • English...
Page 41
Outdoor unit Cushion top Outdoor Unit Packing Case Assy Cushion Base • • English...
Page 42
Appendix Outdoor unit Cushion-top Outdoor unit 4 screws Packing case Wood palette • • English...
Page 43
Product specification Indoor unit : 360CST (AC***TN4F**, AC***TN4L**, AC048TN4FCH/SU) Climate class MODEL (INDOOR UNIT / OUTDOOR UNIT) MODEL CODE (INDOOR UNIT / OUTDOOR UNIT) RATED VOLTAGE & FREQUENCY COOLING RATED CAPACITY HEATING(H1) COOLING RATED CURRENT HEATING(H1) COOLING RATED POWER INPUT HEATING(H1) COOLING EER / COP...
Page 44
Appendix Indoor unit : 360CST (AC***TN4F**, AC***TN4L**) Climate class MODEL (INDOOR UNIT / OUTDOOR UNIT) MODEL CODE (INDOOR UNIT / OUTDOOR UNIT) RATED VOLTAGE & FREQUENCY COOLING RATED CAPACITY HEATING(H1) COOLING RATED CURRENT HEATING(H1) COOLING RATED POWER INPUT HEATING(H1) COOLING EER / COP HEATING(H1) ANNUAL ENERGY CONSUMPTION...
Page 45
Indoor unit : 360CST (AC***TN4F**, AC***TN4L**) Climate class MODEL (INDOOR UNIT / OUTDOOR UNIT) MODEL CODE (INDOOR UNIT / OUTDOOR UNIT) RATED VOLTAGE & FREQUENCY COOLING RATED CAPACITY HEATING(H1) COOLING RATED CURRENT HEATING(H1) COOLING RATED POWER INPUT HEATING(H1) COOLING EER / COP HEATING(H1) ANNUAL ENERGY CONSUMPTION MAX CURRENT...
Page 46
Appendix Indoor unit : 4wayCST (AC***TN4P**) Climate class MODEL (INDOOR UNIT / OUTDOOR UNIT) MODEL CODE (INDOOR UNIT / OUTDOOR UNIT) RATED VOLTAGE & FREQUENCY COOLING RATED CAPACITY HEATING(H1) COOLING RATED CURRENT HEATING(H1) COOLING RATED POWER INPUT HEATING(H1) COOLING EER / COP HEATING(H1) ANNUAL ENERGY CONSUMPTION MAX CURRENT...
Page 47
Indoor unit : 4wayCST (AC***TN4P**) Climate class MODEL (INDOOR UNIT / OUTDOOR UNIT) MODEL CODE (INDOOR UNIT / OUTDOOR UNIT) RATED VOLTAGE & FREQUENCY COOLING RATED CAPACITY HEATING(H1) COOLING RATED CURRENT HEATING(H1) COOLING RATED POWER INPUT HEATING(H1) COOLING EER / COP HEATING(H1) ANNUAL ENERGY CONSUMPTION MAX CURRENT...
Page 48
Appendix Indoor unit : DUCT (AC***TNMP**) Climate class MODEL (INDOOR UNIT / OUTDOOR UNIT) MODEL CODE (INDOOR UNIT / OUTDOOR UNIT) RATED VOLTAGE & FREQUENCY COOLING RATED CAPACITY HEATING(H1) COOLING RATED CURRENT HEATING(H1) COOLING RATED POWER INPUT HEATING(H1) COOLING EER / COP HEATING(H1) ANNUAL ENERGY CONSUMPTION MAX CURRENT...
Page 49
Indoor unit : DUCT (AC***TNMP**) Climate class MODEL (INDOOR UNIT / OUTDOOR UNIT) MODEL CODE (INDOOR UNIT / OUTDOOR UNIT) RATED VOLTAGE & FREQUENCY COOLING RATED CAPACITY HEATING(H1) COOLING RATED CURRENT HEATING(H1) COOLING RATED POWER INPUT HEATING(H1) COOLING EER / COP HEATING(H1) ANNUAL ENERGY CONSUMPTION MAX CURRENT...
Page 50
Appendix Indoor unit : DUCT (AC***TNMP**) Climate class MODEL (INDOOR UNIT / OUTDOOR UNIT) MODEL CODE (INDOOR UNIT / OUTDOOR UNIT) RATED VOLTAGE & FREQUENCY COOLING RATED CAPACITY HEATING(H1) COOLING RATED CURRENT HEATING(H1) COOLING RATED POWER INPUT HEATING(H1) COOLING EER / COP HEATING(H1) ANNUAL ENERGY CONSUMPTION MAX CURRENT...