9.3.3 ExposureAuto
This is auto exposure control function and is effective only in the "Timed"mode.
The brightness is controlled by JAI AGC Reference.
ExposureAuto includes OFF, Once and Continuous modes.
The setting range is;
JAI AGC Reference: 0-255
ExposureTime :
9.4. UserOutputSelector
In addition to TriggerSoftware, the user can use the following commands as the trigger
input sources.
UserOutput1
UserOutput2
UserOutput3
UserOutput4
The setting value is "False" or "True".
9.5. Counter function
This function can count up the internal pulse counts.
9.5.1 CounterSelector
The AT-140GE has one counter.
The counter function is activated by setting ConterEventSource, CounterResetSource
or CounterTriggerSource.
9.5.2 CounterEventSource
CounterEventSource can be selected from the following signals.
CounterEventSource works as the trigger to start the count up.
① Off
② AcquisitionTrigger
③ AcquisitionStart
④ AcquisitionEnd
⑤ FrameStart
⑥ Line 1(TTL out1)
⑦ Line 2(TTL out2)
⑧ Line 3(Opt out1)
⑨ Line 4(Opt out2)
⑩ Line 5(Opt in1)
⑪ Line 6(Opt in2)
⑫ Line 7(TTL in1)
⑬ Line 8(LVDS in)
9.5.3 CounterEventActivation
This selects the timing for when the counter starts up.
RisingEdge: The counting starts at the signal rising edge.
AT-200GE
72L - the maximum value which can be set
- 46 -