DNP ETHERNET PROTOCOL SETTINGS
OBJECT
OBJECT
VARIATION
NO.
NO.
6
21
0
1
2
9
10
22
0
1
23
2
5
6
0
1
2
5
6
3–20
DESCRIPTION
16-Bit Binary Counter
without Flag
Frozen Counter(Variation 0
is used to request
defaultvariation)
32-Bit Frozen Counter
16-Bit Frozen Counter
32-Bit Frozen Counter
without Flag
16-Bit Frozen Counter
without Flag
Counter Change Event
(Variation 0 is used to
request default variation)
32-Bit Counter Change
Event
16-Bit Counter Change
Event
32-Bit Counter Change
Event with Time
16-Bit Counter Change
Event with Time
Frozen Counter Event
(Variation 0 is used to
request default variation)
32-Bit Frozen Counter Event 1 (read)
16-Bit Frozen Counter Event 1 (read)
32-Bit Frozen Counter Event
with Time
16-Bit Frozen Counter Event
with Time
REQUEST
FUNCTION
QUALIFIER CODES
CODES (DEC)
(HEX)
1 (read) 7 (freeze)
00, 01 (start-stop)
8 (freeze noack) 9
06 (no range, or all)
(freeze clear) 10
07, 08 (limited
(frz. cl. noack) 22
quantity) 17, 28
(assign class)
(index)
1 (read) 22
00, 01 (start-stop)
(assign class)
06 (no range, or all)
07, 08 (limited
quantity) 17, 28
(index)
1 (read) 22
00, 01 (start-stop)
(assign class)
06 (no range, or all)
07, 08 (limited
quantity) 17, 28
(index)
1 (read) 22
00, 01 (start-stop)
(assign class)
06 (no range, or all)
07, 08 (limited
quantity) 17, 28
(index)
1 (read) 22
00, 01 (start-stop)
(assign class)
06 (no range, or all)
07, 08 (limited
quantity) 17, 28
(index)
1 (read) 22
00, 01 (start-stop)
(assign class)
06 (no range, or all)
07, 08 (limited
quantity) 17, 28
(index)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
06 (no range, or all)
07, 08 (limited
quantity)
06 (no range, or all)
07, 08 (limited
quantity)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
350 FEEDER PROTECTION SYSTEM – COMMUNICATIONS GUIDE
CHAPTER 3: ETHERNET INTERFACE
RESPONSE
FUNCTION
QUALIFIER CODES
CODES (DEC)
(HEX)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
---
---
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
---
---
129 (response)
17, 28 (index)
130 (unsol.
resp.)
129 (response)
17, 28 (index)
130 (unsol.
resp.)
129 (response)
17, 28 (index)
130 (unsol.
resp.)
129 (response)
17, 28 (index)
130 (unsol.
resp.)
---
---
129 (response)
17, 28 (index)
130 (unsol.
resp.)
129 (response)
17, 28 (index)
130 (unsol.
resp.)
129 (response)
17, 28 (index)
130 (unsol.
resp.)
129 (response)
17, 28 (index)
130 (unsol.
resp.)