DNP PROTOCOL SETTINGS
OBJECT
OBJECT
VARIATION
NO.
NO.
1
23
2
5
6
0
1
2
5
6
30
0
1
2
3
4
32
0
1
2
2–10
DESCRIPTION
32-Bit Counter Change
Event
16-Bit Counter Change
Event
32-Bit Counter Change
Event with Time
16-Bit Counter Change
Event with Time
Frozen Counter Event
(Variation 0 is used to
request default variation)
32-Bit Frozen Counter Event 1 (read)
16-Bit Frozen Counter Event 1 (read)
32-Bit Frozen Counter Event
with Time
16-Bit Frozen Counter Event
with Time
Analog Input (Variation 0 is
used to request default
variation)
32-Bit Analog Input
16-Bit Analog Input
32-Bit Analog Input without
Flag
16-Bit Analog Input without
Flag
Analog Change Event
(Variation 0 is used to
request default variation)
32-Bit Analog Change Event
without Time
16-Bit Analog Change Event
without Time
REQUEST
FUNCTION
QUALIFIER CODES
CODES (DEC)
(HEX)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
06 (no range, or all)
07, 08 (limited
quantity)
06 (no range, or all)
07, 08 (limited
quantity)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
1 (read) 22
00, 01 (start-stop)
(assign class)
06 (no range, or all)
07, 08 (limited
quantity) 17, 28
(index)
1 (read) 22
00, 01 (start-stop)
(assign class)
06 (no range, or all)
07, 08 (limited
quantity) 17, 28
(index)
1 (read) 22
00, 01 (start-stop)
(assign class)
06 (no range, or all)
07, 08 (limited
quantity) 17, 28
(index)
1 (read) 22
00, 01 (start-stop)
(assign class)
06 (no range, or all)
07, 08 (limited
quantity) 17, 28
(index)
1 (read) 22
00, 01 (start-stop)
(assign class)
06 (no range, or all)
07, 08 (limited
quantity) 17, 28
(index)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
1 (read)
06 (no range, or all)
07, 08 (limited
quantity)
350 FEEDER PROTECTION SYSTEM – COMMUNICATIONS GUIDE
CHAPTER 2: RS485 INTERFACE
RESPONSE
FUNCTION
QUALIFIER CODES
CODES (DEC)
(HEX)
129 (response)
17, 28 (index)
130 (unsol.
resp.)
129 (response)
17, 28 (index)
130 (unsol.
resp.)
129 (response)
17, 28 (index)
130 (unsol.
resp.)
129 (response)
17, 28 (index)
130 (unsol.
resp.)
---
---
129 (response)
17, 28 (index)
130 (unsol.
resp.)
129 (response)
17, 28 (index)
130 (unsol.
resp.)
129 (response)
17, 28 (index)
130 (unsol.
resp.)
129 (response)
17, 28 (index)
130 (unsol.
resp.)
---
---
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
129 (response)
00, 01 (start-stop)
17, 28 (index) (see
Note 2)
---
---
129 (response)
17, 28 (index)
130 (unsol.
resp.)
129 (response)
17, 28 (index)
130 (unsol.
resp.)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents