Troubleshooting; S.a.r.a. Booster Function - Beretta EXCLUSIVE GREEN 25 CSI Installation And User Manual

Table of Contents

Advertisement

Available languages

Available languages

S.A.R.A. BOOSTER function

If the winter mode is selected, the S.A.R.A. Booster
function is activated for the heating circuit and reaches
the required ambient temperature more quickly.
GREEN C.S.I. only:
DOMESTIC HOT WATER PRE-HEATING function
If the winter mode is selected, the domestic hot water
Preheating function is enabled. This function sets out to
keep the domestic hot water contained in the boiler hot,
thereby considerably reducing delivery waiting times.
The
function should be selected to reduce power
consumption in areas where the mains water is not
particularly cold.
In this case, the Booster and Preheating (GREEN C.S.I.
only) functions are not activated.

Troubleshooting

When a fault appears on the display, the flame symbol
goes out, a flashing code is shown and the two symbols
and
appear either together or separately.
For a description of the faults, consult the following table.
FAULT
FLAME FAILURE BLOCK (D)
PARASITE FLAME (T)
RE-ATTEMPT IN PROGRESS (T)
MINIMUM GAS INPUT PRESSURE (T)
MINIMUM GAS INPUT PRESSURE (D)
FLAME PRESENT IN STAND-BY FOR NO REASON (D)
LIMIT THERMOSTAT/BURNER THERMOSTAT (D)
SHORT CIRCUIT FUMES PROBE (D)
MAXIMUM TEMPERATURE FUMES PROBE (D)
MAXIMUM TEMPERATURE INPUT PROBE (D)
MAXIMUM TEMPERATURE INPUT PROBE (T)
MAXIMUM TEMPERATURE RETURN PROBE (D)
MAXIMUM TEMPERATURE RETURN PROBE (T)
RETURN-INPUT PROBE DIFFERENTIAL (D)
FUMES PROBE OPEN (D)
FUMES OUTLET OR AIR PRESSURE SWITCH (cycle start) (D)
FUMES OUTLET OR AIR PRESSURE SWITCH (cycle start) (T)
VENTILATOR IN CYCLE (low number of revolutions) (D)
VENTILATOR (cycle start) (D)
VENTILATOR (cycle end) (T)
FUMES OUTLET OR AIR PRESSURE SWITCH (in cycle) (T)
VENTILATOR IN CYCLE (high number of revolutions) (D)
FUMES OUTLET OR AIR PRESSURE SWITCH (in cycle) (D)
INSUFFICIENT SYSTEM PRESSURE (D*)
INSUFFICIENT SYSTEM PRESSURE (T*)
WATER PRESSURE TRANSDUCER (D)
ELECTRONIC BOARD (D)
SANITARY PROBE 1 (T°)
SHORT CIRCUIT/OPEN PRIMARY PROBE (D)
MAXIMUM TEMPERATURE INPUT PROBE (T)
SHORT CIRCUIT/OPEN RETURN PROBE (D)
OVERHEATING/LACK OF WATER CIRCULATION (D)
LOW TEMPERATURE THERMOSTAT (T)
INPUT/RETURN DIFFERENTIAL (T)
INPUT/RETURN DIFFERENTIAL (D)
SYSTEM ANOMALY (D)
Fig. 36
Fig. 37
Alarm
ID
10
11
12
13
14
15
20
21
22
24
25
26
27
28
29
30
31
33
34
35
36
37
38
40
41
42
50-59
60
70
71
72
74
77
78
79
80
21
Symbol
Symbol
YES
NO
NO
YES
NO
NO
NO
YES
YES
NO
YES
YES
YES
NO
YES
YES
YES
NO
YES
NO
NO
YES
YES
NO
NO
YES
YES
YES
YES
YES
YES
NO
NO
YES
YES
YES
YES
NO
NO
YES
NO
YES
YES
YES
YES
YES
YES
NO
NO
YES
YES
YES
YES
YES
NO
YES
YES
YES
NO
NO
YES
YES
YES
NO
NO
YES
NO
YES
YES
NO
YES
YES

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents