Maximum/Minimum Ventilator Speed; Ventilator Igintion Speed; Maximum/Minimum Power Adjustment; Maximum/Minimum Electric Heating Adjustment - Beretta EXCLUSIVE GREEN 25 CSI Installation And User Manual

Table of Contents

Advertisement

Available languages

Available languages

MAXIMUM VENTILATOR SPEED (P. HP)
- Select parameter HP
- Press the ENTER button, then modify the value of the
parameter by turning the sanitary water temperature
selector. The maximum speed of the ventilator is linked
with the type of gas and the power of the boiler
- Turn the sanitary water temperature selector in order to
adjust the set value
- Confirm the new value you have set by pressing
ENTER.
The value indicated on the display is expressed in revs
min/100 (example 3600 = 36).
The value set during this operation automatically modifies
the maximum value of parameter 23.
MINIMUM VENTILATOR SPEED (P. LP)
- Select parameter LP
- Press the ENTER button, then modify the value of the
parameter by turning the sanitary water temperature
selector. The minimum speed of the ventilator is linked
with the type of gas and the power of the boiler
- Turn the sanitary water temperature selector in order to
adjust the set value
- Confirm the new value you have set by pressing
ENTER.
The value indicated on the display is expressed in revs
min/100 (example 3600 = 36).
The value set during this operation automatically modifies
the maximum value of parameter 24.
Maximum power
adjusting screw
Minimum power
adjusting screw
Fig. 51
VENTILA
VENTILA
VENTILAT T T T T OR IGNITION SPEED (P
VENTILA
VENTILA
OR IGNITION SPEED (P
OR IGNITION SPEED (P. . . . . SP)
OR IGNITION SPEED (P
OR IGNITION SPEED (P
- Select parameter SP
- Press the ENTER button, then modify the value of the
parameter by turning the sanitary water temperature
selector. The standard slow start value is 3700 revs/
min
- Confirm the new value you have set by pressing
ENTER.
MAXIMUM POWER ADJUSTMENT - HH
- Turn the boiler OFF
- Select the parameter HH and wait for the boiler to come
on
- Check that the maximum CO
(see paragraph "Checking combustion parameters", page
31) corresponds with the values indicated in table 1.
tabel 1
DESCRIPTION
25 C.S.I. CO
max
2
35 C.S.I. CO
max
2
16 R.S.I. CO
max
2
35 R.S.I. CO
max
2
SP)
SP)
SP)
SP)
reading on the analyser
2
G20
G31
9,0
10,0
%
9,0
10,0
%
8,8
10,0
%
9,0
10,0
%
If the CO
proves to comply with the values in the table,
2
proceed to adjust the next parameter (LL - adjusting the
minimum), if different modify the value by turning the
maximum power adjustment screw with a screwdriver
(clockwise to decrease) until you obtain a value contained
in table 1.
MINIMUM POWER ADJUSTMENT - LL
- Select the parameter LL (with the boiler still OFF) and
wait for the boiler to come on.
- Check that the minimum CO
(see paragraph "Checking combustion parameters", page
31) corresponds with the values indicated in table 2.
tabel 2
DESCRIPTION
25 C.S.I. CO
min
2
35 C.S.I. CO
min
2
16 R.S.I. CO
min
2
35 R.S.I. CO
min
2
If the CO
proves to be different from the values in the
2
table, proceed to adjust the parameter by turning the
maximum power adjustment screw after having
unscrewed the protective cap (clockwise to increase) until
you obtain a value contained in table 2.
IGNITION SPEED (P.MM)
- Select parameter MM.
The boiler starts at the slow ignition speed.
- Turn the heating water selector to increase or decrease
the ventilator speed.
MAXIMUM ELECTRIC HEATING ADJUSTMENT - 23
- Select parameter 23
- Press the ENTER button to access the parameter value
modification function
- Turn the sanitary water selector to modify the maximum
ventilator speed, table 3
- Confirm the value you have set by pressing ENTER.
tabel 3
MAXIMUM NUMBER OF
VENTILATORE REVOLUTIONS
25 C.S.I.
35 C.S.I.
16 R.S.I.
35 R.S.I.
MINIMUM ELECTRIC HEATING ADJUSTMENT - 24
- Select parameter 24
- Press the ENTER button to access the parameter value
modification function, table 4
- Turn the sanitary water selector to modify the minimum
ventilator speed
- Confirm the value you have set by pressing ENTER.
tabel 4
MINIMUM NUMBER OF
VENTILATORE REVOLUTIONS
25 C.S.I.
35 C.S.I.
16 R.S.I.
35 R.S.I.
29
reading on the analyser
2
G20
G31
9,3
10,3
9,0
10,0
8,8
10,0
9,0
10,0
G20
G31
49
51
revs/min
60
60
revs/min
48
48
revs/min
60
60
revs/min
table 4
table 4
table 4
table 4
G20
G31
14
14
revs/min
14
14
revs/min
14
14
revs/min
14
14
revs/min
%
%
%
%

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents