Resetting Faults - Beretta EXCLUSIVE GREEN 25 CSI Installation And User Manual

Table of Contents

Advertisement

Available languages

Available languages

SYSTEM ANOMALY (T)
SYSTEM ANOMALY (D)
SYSTEM ANOMALY (T)
CONDENSATE OR CONDENSATE SENSOR (D)
CONDENSATE OR CONDENSATE SENSOR (T)
CONDENSATE SENSOR OR OPEN CIRCUIT (D)
CONDENSATE SENSOR OR OPEN CIRCUIT (T)
(D) Permanent
(T) Temporary. In this operating status the boiler attempts to eliminate the fault on its own.
(° ° ° ° ° ) For GREEN C.S.I.: see NOTE on this page
For GREEN R.S.I.: only with external water tank with sensor. The fault code is shown when the boiler is in stand-by.
(* * * * * ) If these two errors occur, check the pressure indicated on the water gauge. If the pressure is insufficient (< 0,4 bar, red area), proceed with the filling
operations described in the chapter "Loading and emptying the systems".
If the system's pressure is sufficient (> 0,6 bar, blue area) the malfunction is caused by a lack of water circulation. Contact the Technical Assistance Centre.

Resetting faults

Wait for about 10 seconds before resetting operating
conditions.
Then proceed as follows:
1)
Viewing just the
If
disappears, it means that an operating fault
has been discovered which the boiler is attempting to
solve on its own (temporary stoppage).
If the boiler does not resume normal operation, two
things may happen:
case A (fig. 38)
disappears, the
code appear.
In this case, proceed as described in point 2.
case B (fig. 39)
and a different alarm code are displayed together
with
.
In this case, proceed as described in point 3.
2)
Viewing just the
Press the
button to reset the appliance. If the boiler
starts the ignition phase and resumes normal operation,
it may have stopped by accident.
If these stoppages should continue, contact the Technical
Assistance Centre.
Fig. 40
3) Viewing the
Contact the Technical Assistance Centre.
Fig. 41
For GREEN C.S.I. only:
Note
Fault in domestic hot water circuit sensor - 60: the
boiler works regularly but does not ensure the stability of
the hot water temperature which, however, is delivered
at a temperature of approximately 50°C.
The fault code is only displayed in standby.
symbol
symbol and a different alarm
symbol (fig. 40)
and
symbols (fig. 41)
81
82
83
92
93
94
95
CASE A
Fig. 38
CASE B
Fig. 39
22
NO
YES
NO
YES
NO
YES
NO
temporary fault
permanent fault
temporary fault
permanent fault
YES
YES
YES
NO
YES
YES
YES