WG‐500P Hotspot in a Printer 
 
 
PPP MTU Setting
1492
 
 
TCP MSS Setting
1452
 
Service Name
Empty
Connect on Demand and Max Idle Time
Connect on
Enable
Demand
 
10 Minutes
Max Idle Time
Keep alive and Redial Period
 
Keep alive
Disable
 
30 Seconds
Redial Period
 
 
 
up to 80 alphanumeric characters and is case sensitive.
MTU (Maximum Transfer Unit) specifies maximum transmission unit size.
MSS (Maximum Segment Size) specifies maximum segment size.
 
Enter the service name provided by your ISP. The service name can consist
of up to 64 alphanumeric characters and is case sensitive.
 
 
You can configure your WG-500P to cut your connection with your ISP after a
specified period of time (Max Idle Time). If you have been disconnected due
to inactivity, Connect on Demand enables your WG-500P to automatically
re-establish your connection as soon as you attempt to access the Internet
again. If you wish to activate Connect on Demand, click the radio button. If
you want your Internet connection to remain, click the radio button of keep
alive. The Max Idle Time maximum value is 65535 minutes.
 
 
This option keeps your PPPoE enabled Internet access connected
indefinitely, even when it sits idle. The Redial Period maximum value is 65535
seconds.
 