SWIM SPA TROUBLE SHOOTING GUIDE
Note: For wiring outside of U.S. and Canada, GFCI may be referred to as a RCD (residual current device).
Be sure all local electrical codes are followed.
NOTHING ON THE SWIM SPA OPERATES
1. Check the control panel display for any messages. If there is a message, refer to the diagnostic sec-
tion on that model swim spa. There, you will find the meaning of the message and what action is
to be taken.
2. If there is no message on the control panel, check, and reset the GFCI breaker.
If the swim spa does not respond, contact your local service company.
PUMP(S) DO NOT OPERATE -
1. Press the "Jets" button on your control panel.
If you hear the pumps trying to operate:
A. Check that all the slice valves are open.
B. Pump may need to be primed.
C. Check that the air controls are open.
If you do not hear anything from the pump, contact your local service company.
POOR JET PERFORMANCE
1. Make sure pump is operating
2. Check that the water level is adequate (up to minimum safe water level side)
3. Make sure the jets are open and the air controls are open.
4. Check for dirty filters. Clean if necessary.
DO NOT DIVE.
DO NOT DIVE.
The swim spa GFCI breaker or disconnect should be located
in a weather proof box close to the swim spa.
100