IKH IKH7255 Instruction Manual page 32

Circular saw for metal
Table of Contents

Advertisement

Available languages

Available languages

4.2 - Transport and handling of the machine
If the machine has to be shifted
in its own packing, use a fork-
lift truck or sling it with straps
as illustrated.
4.3 - Minimum requirements for the premises housing the machine
Mains voltage and frequency complying with the machine motor characteristics.
Environment temperature from -10°C to +50°C.
Relative humidity not over 90%.
4.4 - Anchoring the machine
Position the machine on a firm cement floor,
maintaining, at the rear, a minimum distance of
800 mm from the wall; anchor it to the ground
as shown in the diagram, using screws and ex-
pansion plugs or tie rods sunk in cement, ensur-
ing that it is sitting level.
4.5 - Instructions for electrical connection
The machine is not provided with an electric plug, so the customer must fit a suitable one for his
own working conditions:
1. Wiring diagram for 5-wire system with neutral for three-
phase machine – socket for a 16A plug
2. Wiring diagram for the single-phase system – socket for
16A plug
4.6 - Instructions for assembly of the loose parts and accessories
Fit the components supplied as indicated in the photo:
part 1. Screw the lever onto the head and fix it
part 2. Fit the bar holding rod
part 3. Fix the pedestal firmly onto the base