  • Page 1 F2X64 Series User Manual The user manual is suitable for the following model: Model Product Type F2164 GPRS RTU F2264 CDMA RTU F2464 WCDMA RTU Xiamen Four-Faith Communication Technology Co., Ltd. Add:J1-J3,3rd Floor,No.44,GuanRi Road,SoftWare Park,XiaMen,China Zip Code:361008 Tel:+86 592-6300326 ,6300325,6300324 Fax:+86 592-5912735 http://www.fourfaith.com...
  • Page 2 1. Add the sms command to read input value Xingfa.lin 2. Add the sms command to control output 2015-5-28 V1.4 1. Add ADC sample type description Xiamen Four-Faith Communication Technology Co.,Ltd. Page 2 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 3: Copyright Notice

    Four-Faith Communication Technology Co., Ltd. Without written permission, all commercial use of the files from Four-Faith are forbidden, such as copy, distribute, reproduce the files, etc., but non-commercial purpose, downloaded or printed by individual (all files shall be not revised, and the copyright and other proprietorship notice shall be reserved) are welcome.
  • Page 4 F2X64 User Manual Xiamen Four-Faith Communication Technology Co.,Ltd. Page 4 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 5: Table Of Contents

    ◆ Digital input function..................31 ◆ MODBUS logic corresponding function............32 ◆ Acquisition purpose..................32 ◆ Acquisition interval..................32 ◆ Alarm trigger condition................33 Xiamen Four-Faith Communication Technology Co.,Ltd. Page 5 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 6 4.1.4.6 Data Service Center Settings................ 49 ◆ Data Center Number................... 49 ◆ Main Center Addr+Port:................50 ◆ Backup Center Addr+Port:................50 ◆ Multi DSC Configuration................51 Xiamen Four-Faith Communication Technology Co.,Ltd. Page 6 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel:...
  • Page 7 ◆ Show Baudrate.................... 75 ◆ Auto Detect....................75 ◆ Version Display................... 75 ◆ Signal Value....................75 ◆ Factory setting.....................76 ◆ Clear Output....................76 Xiamen Four-Faith Communication Technology Co.,Ltd. Page 7 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 8 5.2.8 Center service information..................91 5.2.9 Query data........................ 92 5.2.10 Remote configure....................93 5.2.11 Upgrade........................93 5.2.12 Reset device......................94 Appendix............................96 Xiamen Four-Faith Communication Technology Co.,Ltd. Page 8 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 9: Chapter 1 Brief Introduction Of Product

     SIM/UIM port: 15KV ESD protection  Power port: reverse-voltage and overvoltage protection  Antenna port: lightning protection(optional) Standard and Convenient  Adopt terminal block interface, convenient for industrial application Xiamen Four-Faith Communication Technology Co.,Ltd. Page 9 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel:...
  • Page 10  Support RTU extended protocol. It has counter function that the initial value of the timer is set and the value of the timer is queried  Support RTU extended protocol. It has the data center and RS232/RS485 transparent transmission function Xiamen Four-Faith Communication Technology Co.,Ltd. Page 10 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com...
  • Page 11: Working Principle

    RTC Module FLASH WDT Module Indicator Lights Antenna Cellular RS232/RS485/RS422 Module Module SIM/UIM Interface Power Module User Interface Xiamen Four-Faith Communication Technology Co.,Ltd. Page 11 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 12: Specifications

    Cellular: Standard SMA female interface, 50 ohm lighting protection(optional) SIM/UIM Standard 3V/1.8V user card interface, 15KV ESD protection Power Terminal block interface, reverse-voltage and overvoltage protection Xiamen Four-Faith Communication Technology Co.,Ltd. Page 12 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 13 157x97x25 mm Weight 500g Environmental Limits Item Content Operating -35~+75ºC(-31~+167℉) Temperature Storage -40~+85ºC(-40~+185℉) Temperature Operating 95% ( Non-condensing) Humidity Xiamen Four-Faith Communication Technology Co.,Ltd. Page 13 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 14: Chapter 2 Installation Introduction

    Maintenance card Table 2-1 Encasement List 2.3 Installation and Cable Connection Dimension : (unit: mm) Figure 2-1 Installation Chart Xiamen Four-Faith Communication Technology Co.,Ltd. Page 14 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 15 None output Optocoupler output None COM GND None Relay Relay output 1- None output Relay output 1+ None Xiamen Four-Faith Communication Technology Co.,Ltd. Page 15 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 16 Cathode RS232 Cable: Cable Color Corresponding DB9-M Pin Number Brown Pin 2 Blue Pin 3 Black Pin 5 Xiamen Four-Faith Communication Technology Co.,Ltd. Page 16 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 17 Black RS485(B) Power adapter and communication cable connection chart as following: Digital Input cable connection Wet contact Dry contact Xiamen Four-Faith Communication Technology Co.,Ltd. Page 17 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 18 User Manual cable connection Optocoupler output Relay output cable connection Xiamen Four-Faith Communication Technology Co.,Ltd. Page 18 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 19: Power

    RTU is powered off BLINK Data is communicating No data Online RTU has logged on network RTU hasn’t logged on network Xiamen Four-Faith Communication Technology Co.,Ltd. Page 19 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 20: Chapter 3 Rtu Function Introduction

    Enable MODBUS function, related settings please refer to appendix 4.1.4.5 ModBus Setting, it also need to configure the digital input, digital output, analog input and counter input Xiamen Four-Faith Communication Technology Co.,Ltd. Page 20 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com...
  • Page 21: Tcp2Com Description

    Slave Function IO status value Checksum Data length Address code Meaning Read input status value, checksum Data length Xiamen Four-Faith Communication Technology Co.,Ltd. Page 21 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 22: Modbus Digital Io Output Introduction

    1-4, address 4-7 used for relay outputs,corresponding to rlay output 1-4). The MODBUS configuration of readding digital IO output please refer to appendix 4.1.4.2 Optocoupler and relay settings. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 22 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel:...
  • Page 23: Modbus Counter Introduction

    4.1.4.4 RTU counter settings. Read counter value, command as following: 01 03 00 00 00 02 C4 0B Parse command: Xiamen Four-Faith Communication Technology Co.,Ltd. Page 23 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 24 32 bits, so need count high 16 bits of counter to write two 16 counter value register bits registers Xiamen Four-Faith Communication Technology Co.,Ltd. Page 24 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 25: Modbus Analog Input Introduction

    32 bits, high 16 register AIN1-AIN8 bits first. If read one channel, this parameter should be 0002 Xiamen Four-Faith Communication Technology Co.,Ltd. Page 25 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 26: Rtu Extended Protocol

    The data center can query acquisition data actively It has counter function that the initial value of the counter can be configured, its realtime value can be queried Xiamen Four-Faith Communication Technology Co.,Ltd. Page 26 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com...
  • Page 27: Alarm Function

    SMS or RTU extended protocol. When RTU received the valid upgrade parameters, it will upgrade the firmware automatically. Detail settings please refer to appendix 4.2.2.2 Overall setting by SMS 5.10 Remote configure. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 27 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel:...
  • Page 28: Chapter 4 Configuration

    The following describes how to configure RTU with the configure software tool. At the same time, it gives out the corresponding AT command of each configuration item. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 28 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China...
  • Page 29: Run The Configure Tool

    If the text is “Open”, you should open the port first. When the port opened, the “Output Info” column will display “Port(COM1) Has Opened,Please Re-Power the RTU, Waiting RTU Enter Configure State...” Xiamen Four-Faith Communication Technology Co.,Ltd. Page 29 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com...
  • Page 30: Re-Power Rtu

    After Re-power RTU, The configure tool will make it enter configure state. At the same time, the software will load current settings from RTU and displays on the right configure columns. It’s now ready to configure. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 30 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China...
  • Page 31: Configuration

    Explanation: enable or disable switch of digital input Parameter: y range 1~8, Corresponding to digital input channel 1 ~ 8. x range 0~1, 0 means disable,1 means enable. Example: AT+RTUINIOEN1=1 Xiamen Four-Faith Communication Technology Co.,Ltd. Page 31 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel:...
  • Page 32: Modbus Logic Corresponding Function

    Explanation: set acquisition interval. Parameter: y range 1~8, corresponding to digital input channel 1~8. x range 0-4294967295,0 means close acquisition function.. Example: AT+RTUINIOTIME1=6000 Xiamen Four-Faith Communication Technology Co.,Ltd. Page 32 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 33: Alarm Trigger Condition

    7). Example: AT+RTUINIOSETLRMNO1=13912345678,13812345678 Command: AT+RTUINIODELLRMNOy=xxx Xiamen Four-Faith Communication Technology Co.,Ltd. Page 33 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 34: Optocoupler And Relay Settings

    1~8, corresponding to digital output channels(1~4 corresponding to optocouplers channel 1~4, 5~8 corresponding to relay outputs 1~4). x range 0-1, 0 means disable, 1 means enable. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 34 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com...
  • Page 35: Modbus Logic 1 Output

    Explanation: MODBUS logic 1 square wave cycle. Parameter: y range 1~4, corresponding to digital output channels(1~4 corresponding to optocoupler ports 1~4). x range 0-4294967295. Example: AT+RTUOUTIOONEFREQ1=50 Xiamen Four-Faith Communication Technology Co.,Ltd. Page 35 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 36: Modbus Logic 0 Square-Wave Cycle

    1~4, 5~8 means relay output 1~4). Optocoupler output: x range 0-1,0 means low level,1 means high level. relays: x range 0-1,0 means disconnet,1 means connect. Example: AT+RTUOUTIODEFVAL1=1 Xiamen Four-Faith Communication Technology Co.,Ltd. Page 36 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel:...
  • Page 37: Analog Channel Settings

    1.3 ~ 4.5V. This sensor connect to RTU fisrt analog input channel. The decimal point of the data is three. temperature that is higher than 39.9℃ lower than -20.5℃ should alarm. The parameter settings should as following. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 37 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China...
  • Page 38 1~8, corresponding to input channel 1~8. x range -2147483648 to 2147483647,its value related to the decimal point. Example: AT+RTUADCZEROVAL1=100 Example: AT+RTUADCZEROVAL1=-100 Command: AT+RTUADCLOWERVALy=x Xiamen Four-Faith Communication Technology Co.,Ltd. Page 38 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 39: Set Sensor Voltage Or Current Output

    1~8, corresponding to analogl input channel 1~8. x range 0-4294967295,it related to the sensor ouput type Example: assume the analog signal input type is current. AT+RTUADCZEROVORA1=1000000 (1mA) Xiamen Four-Faith Communication Technology Co.,Ltd. Page 39 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com...
  • Page 40: Modbus Function

    0-4294967295,0 means close acquisition function. Example: AT+RTUADCTIME1=1 ◆ Alarm trigger condition It will alarm if analog input match this condition. Command: AT+RTUADCLRMOPy=x Xiamen Four-Faith Communication Technology Co.,Ltd. Page 40 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 41: Alarm Content

    Parameter: y range 1~8, corresponding to analog input channel 1~8. xxx mean alarm phone number to be deleted(can configure multiple phone numbers, the numbers are separated by Xiamen Four-Faith Communication Technology Co.,Ltd. Page 41 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com...
  • Page 42: Active Report Function

    All the RTU counter settings are configured in this page. Counter and digital input channel 1 are the same pin, Therefore two functions can not be enabled at the same time. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 42 of 98 Add:...
  • Page 43: Counter Function

    Command: AT+RTUCOUNTERLRMREN=x Explanation: enable or disable counter alarm function. Parameter: x range 0-1,0 means disable, 1 means enable. Example: AT+RTUCOUNTERLRMREN=0 Xiamen Four-Faith Communication Technology Co.,Ltd. Page 43 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 44: Alarm Content

    Example: AT+RTUCOUNTERDELLRMNO=13912345678,13812345678 ◆ Alarm upper limit Counter alarm when “Alarm function” enable and counter value is greater than this “Alarm upper limit” value. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 44 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 45: Active Report Interval

    If this parameter configured as zero, RTU report alarm information only once. Command: AT+RTULRMTIME=x Xiamen Four-Faith Communication Technology Co.,Ltd. Page 45 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com...
  • Page 46: Continuous Alarm Number Of Times

    Parameter: xxx means alarm phone numbers(can configure multiple phone numbers, the numbers are separated by comma,total numbers should not exceed 7). Example: AT+RTUDELADMINNO=13912345678,13812345678 Xiamen Four-Faith Communication Technology Co.,Ltd. Page 46 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 47: Modbus Setting

    Explanation: set MODBUS functions work mode. Parameter: x range 0-2,0 means Disable MOBUS,1 means Network RTU, 2 means Serial Port RTU. Example: AT+MBMODE=1 Xiamen Four-Faith Communication Technology Co.,Ltd. Page 47 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 48: Modbus Address

    Command: AT+RTUWRKMDE=x Explanation: set RTU work mode. Parameter: x range 0-1, 0 mean no wireless module, 1 mean has wireless module. Example: AT+RTUWRKMDE=1 Xiamen Four-Faith Communication Technology Co.,Ltd. Page 48 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 49: Data Service Center Settings

    If the Data Center Number is 1, RTU work in Main and Backup DSC mode. When “Data Center Number” is greater than 1, RTU works in Multi Data Service Center mode Xiamen Four-Faith Communication Technology Co.,Ltd. Page 49 of 98 Add:...
  • Page 50: Main Center Addr+Port

    IP address and port of the Backup DSC AT command of the Backup DSC IP address or domain: AT+IPSEC=xxx xxx: The IP address or domain name Xiamen Four-Faith Communication Technology Co.,Ltd. Page 50 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com...
  • Page 51: Multi Dsc Configuration

    10-11, 10 means MODBUS, 11 means RTU extended protocol. Example: Set IP address of center 3 as 166.111.8.238, and port 5001, the AT command is as following: Xiamen Four-Faith Communication Technology Co.,Ltd. Page 51 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel:...
  • Page 52: Main And Backup Center Dns Server

    DNS server is used to resolve center 2~5 correspondingly. AT command of 2~5 DNS Server AT+DNSSVRn=aaa.bbb.ccc.ddd n is 1~4 correspond to center 2~5 DNS server. aaa.bbb.ccc.ddd is the DNS server IP address Xiamen Four-Faith Communication Technology Co.,Ltd. Page 52 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel:...
  • Page 53: Device Settings

    TCPCON: All data interaction based on the TCP link. UDPCON: All data interaction based on the UDP link. AT command: AT+MODE=xxxx xxxx: one of the above workmode Xiamen Four-Faith Communication Technology Co.,Ltd. Page 53 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel:...
  • Page 54: Trigger Type

    0-1, 0 means disable, 1 means enable ◆ Debug Level Debug information is used to debug software when there is software problem. 0 --- no debug information output Xiamen Four-Faith Communication Technology Co.,Ltd. Page 54 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com...
  • Page 55: Databit, Parity, Stopbit

    38400 --- 38400 bps 56000 --- 56000 bps 57600 --- 57600 bps 115200 --- 115200 bps AT Command: Xiamen Four-Faith Communication Technology Co.,Ltd. Page 55 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 56: Auto Back To Main Server

    ◆ SIM Card No The phone number of the SIM card . AT Command: AT+PHON=xxxxxxxxxx xxxxxxxxxxx: the SIM card phone number Xiamen Four-Faith Communication Technology Co.,Ltd. Page 56 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 57: Bytes Interval

    This item is only valid when the WorkMode is TCST. It’s the self defined heartbeat string, It can be empty, the maximum length is 70 bytes. AT Command: AT+LINKRGST=xxx xxx:self defined heartbeat string Xiamen Four-Faith Communication Technology Co.,Ltd. Page 57 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel:...
  • Page 58: Reconnect Setting

    <<RTU Transfer Meaning Explanation In the PROT work mode>>. If this item is set to 1, all the transmission is transparent. AT Command: AT+STRAIGHT=x x:0 or 1 Xiamen Four-Faith Communication Technology Co.,Ltd. Page 58 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel:...
  • Page 59: Other Settings

    Normally, the device Model and the parameters can configured as the following,if this can not work please inquiry your local mobile operators for the corresponding settings. Model Username Call center Xiamen Four-Faith Communication Technology Co.,Ltd. Page 59 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel:...
  • Page 60: Sms Center

    AT Command: AT+SMSC=xxx xxx: your local SMS center number ◆ Heartbeat Interval Time interval sent heartbeat packet. (unit is second) Xiamen Four-Faith Communication Technology Co.,Ltd. Page 60 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 61: Call Trigger Phone No

    It will return to the idle state when receives trigger off data. AT Command of Data Trigger On Password: AT+DONPSWD=xxx xxx : data trigger on password Xiamen Four-Faith Communication Technology Co.,Ltd. Page 61 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel:...
  • Page 62: Tcp Mtu

    Command: AT+SMSCF=x Explanation: whether SMS configure function is enabled. Parameter: x range 0-1, 0 mean disable, 1 mean enable. Example: AT+SMSCF=1 Xiamen Four-Faith Communication Technology Co.,Ltd. Page 62 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 63: Scheduled Power On/Off Setting

    4.1.4.9 Scheduled Power ON/OFF Setting ◆ RTC(Real Time Clock) Time Setting Click “ ” to ensure the setting AT Command: AT+EXCCLK="yyyy/mm/dd,HH:MM:SS",W Xiamen Four-Faith Communication Technology Co.,Ltd. Page 63 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 64: Power On/Off Setting

    M -- per Month. Set a time point of every month I -- Interval. Set the time interval. P -- Power always on. C -- Count down. Set the count down length. 1. Disable Xiamen Four-Faith Communication Technology Co.,Ltd. Page 64 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel:...
  • Page 65 <holdTime>: Hold time value.(Unit:Second) For example: RTU power on at 12:30:00, and power off at 13:30:00 on August 1st,2010 AT+EXCAL5=OT,"2010/08/01,12:30:00",3600 3. Power on per hour Xiamen Four-Faith Communication Technology Co.,Ltd. Page 65 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel:...
  • Page 66 RTU power on at the 30th minute in every hour, and power off 10 minutes later. AT+EXCAL1=OH,"00:30:00",600 4.Power on per day AT Command: AT+EXCALx=OD,<strTime>,<holdTime> <strTime>: Format "12:30:00" <holdTime>: Hold on value(Unit:Second) For example: Xiamen Four-Faith Communication Technology Co.,Ltd. Page 66 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 67 RTU power on at 09:00:00 on every Wednesday and Friday, and power off 1 hour later. AT+EXCAL1=OW,35,"09:00:00",3600 The “35” replace to Wednesday and Friday. 6.Power on per month Xiamen Four-Faith Communication Technology Co.,Ltd. Page 67 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com...
  • Page 68 RTU power on at 09:00:00 on the 28th every month,and power off 1 hour later. AT+EXCAL3=OM,28,"09:00:00",3600 7.Power on with time interval AT Command: AT+EXCALx=OP,<intervalTime>,<holdTime> Xiamen Four-Faith Communication Technology Co.,Ltd. Page 68 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 69 RTU online interval every 10 minute, and offline 120 seconds later. AT+EXCAL1=OP,10,120 Note: RTU not power off in this mode, it is standby. 9.Power off at one time Xiamen Four-Faith Communication Technology Co.,Ltd. Page 69 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com...
  • Page 70 User Manual AT Command: AT+EXCALx=ST,<strTime> 10.Power off per hour AT Command: AT+EXCALx=SH,<strTime> 11.Power off per day Xiamen Four-Faith Communication Technology Co.,Ltd. Page 70 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 71 AT Command: AT+EXCALx=SD,<strTime> 12.Power off at the same time in every week AT Command: AT+EXCALx=SW,<week>,<strTime> 13.Power off per month Xiamen Four-Faith Communication Technology Co.,Ltd. Page 71 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 72 <afterTime>: Countdown value(Unit:Second) For example: RTU power off 600 seconds later: AT+EXCAL1=SC,60 Note: If the <aftertime> is 0,the RTU will power off immediately. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 72 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 73: Sms Setting

    SMS. This parameter used for setting SMS destination number. Five phone numbers can be configured at each group, Each phone numbers are separated by Xiamen Four-Faith Communication Technology Co.,Ltd. Page 73 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China...
  • Page 74: Sms Sending Format

    SMS. AT Command: AT+OPENSMSBCKP=x x range 0-2 0 means Network Only, 1 means SMS Only, 2 means Main network SMS backup Xiamen Four-Faith Communication Technology Co.,Ltd. Page 74 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel:...
  • Page 75: Functions

    ◆ Auto Detect Simple way to determine whether RTU work fine ◆ Version Display Show the software and hardware version ◆ Signal Value Xiamen Four-Faith Communication Technology Co.,Ltd. Page 75 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 76: Factory Setting

    ◆ Save Configure Save the current settings to a file, you can restore it from this file later ◆ Load Configure Load parameters from a file. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 76 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com...
  • Page 77: Work State Switch

    RTU will send one response SMS to user. SMS content: command(Corresponding settting command): Configure successful. setting failed: will send response user, content: Xiamen Four-Faith Communication Technology Co.,Ltd. Page 77 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 78: Setting Remote Upgrade

    1~4, 5~8 means relay output 1~4). Optocoupler output: x range 0-1,0 means low level,1 means high level. relays: x range 0-1,0 means disconnet,1 means connect. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 78 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com...
  • Page 79: Read Analog Input

    Parameter: none. Example: <123456;RTUADCVALTEST> 4.3 Setting for RTU extended protocol RTU extended protocol configuration, please refer to appendix 5.2.10 Remote configure. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 79 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 80: Chapter 5 Software Manual

    5.1.2 Install the driver Before using virtual serial port, you must install the driver of virtual serial port with the following steps : Xiamen Four-Faith Communication Technology Co.,Ltd. Page 80 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel:...
  • Page 81 ,then click OK to install the driver. Then the PC will install device driver,and show whether the driver has been installed successfully as following. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 81 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China...
  • Page 82: Add Virtual Serial Port

    Click “Add Tunnel”,Set the params according to the serial port property. Note: Set the transfer tunnel parameters in this interface, the setting as above set the Device ID of Xiamen Four-Faith Communication Technology Co.,Ltd. Page 82 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China...
  • Page 83 A、Different ID of RTU can transfer to one same serial port,but it can not transfer one ID of RTU to multiple serial ports. B、Tunnel Manger can also Modify and Delete the exist tunnel.Current version support 5000 tunnels at most. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 83 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com...
  • Page 84: Setting The Server Parameters

    After setting the parameters of tunnel and server,click menu “Operation”->”Start service” or just press button ,the software will start to listening and waiting the connection from RTU. Here is the state of id of 74736574 RTU not connected Xiamen Four-Faith Communication Technology Co.,Ltd. Page 84 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com...
  • Page 85: Monitor

    ,it will show the monitor window which can show outbound and inbound data as following.if you want to monitor one tunnel ,just click the left tree id,it will show the selected id data. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 85 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China...
  • Page 86: Not Transmited Data Query

    RTU but transfer to serial port failed as following , Also you can just open the database file “Info.mdb”(Access Database file),find table “NotTransData” to query the data. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 86 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China...
  • Page 87: Delete Database Data

    Click menu “Database”->”Delete saved data”,or press button , you can delete the data by device ID,also you can delete all of the data in database ,the dialog as below Xiamen Four-Faith Communication Technology Co.,Ltd. Page 87 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China...
  • Page 88: Quit

    Click menu “Operation”->”Exit”,or press button ,it will show as below Press OK to quit TCP2COM. 5.2 RTU center service 5.2.1 Open software Xiamen Four-Faith Communication Technology Co.,Ltd. Page 88 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324...
  • Page 89: Service Setting

    “Offline Time” is interval that center software scan equipment time. “Service Style” is the style of the network. Configuration parameters accord to the actual situation . Please click “OK” after configuration 5.2.3 Start equipment and connect Xiamen Four-Faith Communication Technology Co.,Ltd. Page 89 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com...
  • Page 90: View The Acquisition Data

    5.2.5 Send data to RS232/RS485 First select a different device ID, second input content in the edit window, then click “Send” button. Then, RTU RS232/RS485 will send out this content. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 90 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com...
  • Page 91: Control Optocoupler And Relay

    5.2.7 Alarm information Can view different device and diffent alarm information that includes alarm type, channel address, acquisition value and acquisition time. 5.2.8 Center service information Xiamen Four-Faith Communication Technology Co.,Ltd. Page 91 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com...
  • Page 92: Query Data

    Please click it, then appear as follow picture. Please select the channel, then click “query Acquisition info” button. It also can query counter value, when click “Query Counter” button. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 92 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China...
  • Page 93: Remote Configure

    When need to upgrade, please contact the us to get the server address and software version. Select the device ( click the check box in front of the device ID), Please click icon or operate as following picture. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 93 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com...
  • Page 94: Reset Device

    5.2.12 Reset device Select the device ( click the check box in front of the device ID), Please click icon or operate as following picture. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 94 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel:...
  • Page 95 User Manual If click this button, RTU will reboot. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 95 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...
  • Page 96: Appendix

    3. Choose the correct COM port which connect to RTU, choose “OK” 4. Configure the serial port parameters as following, choose “OK” Bits per second: 115200 Xiamen Four-Faith Communication Technology Co.,Ltd. Page 96 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com...
  • Page 97 5. Complete Hyper Terminal operation, It runs as following Re-power RTU, put mouse focus on the Hyper Terminal and press “s” key continuously until RTU enter configure state as following Xiamen Four-Faith Communication Technology Co.,Ltd. Page 97 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China...
  • Page 98: Xiamen Four-Faith Communication Technology Co.,Ltd

    User Manual 7. RTU has entered configure state, you can configure the parameters by AT command. Xiamen Four-Faith Communication Technology Co.,Ltd. Page 98 of 98 Add: J1-J3,3 Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Fax:+86 592-5912735...