FORMS FEED EMITTER DISK
Adjustment
The disk should be centered in the photocell assembly
opening for all positions of the disk.
1.
Remove the forms motor and emitter assembly
(126).
2.
Remove the outer cover
1m .
3.
Loosen the clamp collar
m
and center the disk in
the opening. Do not scratch the black paint from
around the disk holes. A 0.76 mm (0.030 inch)
thickness gauge should slide freely on the upper
si~e
of the disk. Check the gap at several points
on the disk.
Forms Feed Motor
(rotated 90
0
clockwise)
126, 127
Remove, Replace,
Adjust
4.
Tighten the clamp collar and check the gap.
5.
Reinstall the outer cover.
6.
Reinstall the motor and emitter assembly (126).
~ ~
0.63 mm
to
0.88 mm
I
(0.025
inch to
0.035
inch)
Ddl
Maintenance
5256
MIM
1-25