Maintenance
Solution Strainer
Located in bottom of tank. Protects system from debris.
Solenoid Valve
The solenoid valve is mounted on the back of the scrub
deck, on left side. The solenoid valve opens and closes
to meter the correct amount of solution to the scrub
deck.
The solenoid valve shuts off solution flow to scrub deck
whenever scrubbing stops.
To repair or replace solenoid valve:
1. Remove 1 screw to remove sheet metal cover.
2. Disconnect 2 electrical connectors.
3. Loosen hose clamps for both hoses.
4. Pull both hoses off valve.
5. Remove 2 screws securing valve to mounting
bracket.
6. Reverse process to install.
Solution Manifold
The solution manifold supplies solution equally along
the length of the brush. The manifold can be removed
by releasing the quick disconnect at the right side of the
brush deck. The manifold should be cleaned daily for
best results.