Foundry Hardware Installation Guide for the FES, FESX, and FWSX

Regulatory Compliance

Table 7.3 lists the Electromagnetic Compatibility (EMC), Immunity standards, and safety agency approvals for the
FastIron family of switches.

Power Source Interruptions

Table 7.4 shows how the FastIron compact switch protects against power surges and power drops.
Property
Power surge
Power drop (<=1 second)
Maximum power draw

Mean Time Between Failure

Table 7.5 lists the Mean Time Between Failure (MTBF) for the FastIron compact switches. The MTBF is the
average estimated time, in units of hours, before a hardware failure may occur.
7 - 4
Table 7.3: Regulatory Compliance
Certifications
Emissions:
CISPR-22 Class A
EN 55022
FCC Class A
VCCI Class A
Electromagnetic:
Generic: EN 50082-1
Table 7.4: Power Surge and Drop Protection
© 2008 Foundry Networks, Inc.
Protection Mechanism
MOV and Spark Gap protection
An AC loss of >15ms will cause the
power supply to shut down due to
input under-voltage
195 watts with 2-port 10-Gigabit
uplinks
110 watts without 2-port 10-Gigabit
uplinks