This chapter contains information about refining the configuration of, monitoring, and managing the following
components:
•
Temperature settings for the FES
•
Temperature and fan settings for the FESX and FWSX
•
Management module CPU usage
•
MAC address entries (removing)
Viewing the Chassis Type
If your device is running software release FSX 04.3.00 or later (for the FESX, FESXE, and FWSX), the output of
the show chassis command displays the chassis type. For example:
SW-FESX424F Switch#show chassis
Chassis Type: FESX424HF-PREM
Power supply 1 (NA - NA - Regular) present, status ok
Power supply 2 not present
Fan 1 ok
Fan 2 ok
Exhaust Side Temperature Readings:
Current temperature : 15.0 deg-C
Warning level.......: 85.0 deg-C
Shutdown level......: 90.0 deg-C
Intake Side Temperature Readings:
Current temperature : 14.0 deg-C
Boot Prom MAC: 000c.dbda.79a0
Managing FES Temperature Settings
This section describes how to display temperature settings on the FES switch and how to change the temperature
warning and shutdown levels.