P0816 - Gateway 1; P0817 - Gateway 2; P0818 - Gateway 3; P0819 - Gateway 4 - WEG SCA06 User Manual

Ethernet communication module
Hide thumbs Also See for SCA06:
Table of Contents

Advertisement

The following table shows the allowed values for the CIDR notation and equivalent dot notation for the subnet mask:
NOTE!
For the changes in this parameter be effective, the equipment must be powered off and on again, or
an update must be performed by P0849.
P0816 – GATEWAY 1
P0817 – GATEWAY 2
P0818 – GATEWAY 3
P0819 – GATEWAY 4
Range:
Properties:
Description:
If P0810 = 0 (parameters), these parameters allow you to program the IP address of the default gateway for the
Ethernet modules. For other option of P0810, these parameters have no function.
Each parameter programs one octet of the gateway address, where the P0816 is the most significant octet. The
programmed gateway IP address, then, has the format "P0816.P0817.P0818.P0819".
NOTE!
For the changes in this parameter be effective, the equipment must be powered off and on again, or
an update must be performed by P0849.
P0820 ... P0831 – ETHERNET READ WORDS #5 ... #16
Range:
Properties:
Description:
These parameters allow programming the number of read words (inputs: slave → master), as well as the content of
Table 5.5: P0815 options
CIDR
Sub-net mask
1
128.0.0.0
2
192.0.0.0
3
224.0.0.0
4
240.0.0.0
5
248.0.0.0
6
252.0.0.0
7
254.0.0.0
8
255.0.0.0
9
255.128.0.0
10
255.192.0.0
11
255.224.0.0
12
255.240.0.0
13
255.248.0.0
14
255.252.0.0
15
255.254.0.0
16
255.255.0.0
0 ... 255
RW, ETH
0 ... 9999
RW, ETH
CIDR
Sub-net mask
17
255.255.128.0
18
255.255.192.0
19
255.255.224.0
20
255.255.240.0
21
255.255.248.0
22
255.255.252.0
23
255.255.254.0
24
255.255.255.0
25
255.255.255.128
26
255.255.255.192
27
255.255.255.224
28
255.255.255.240
29
255.255.255.248
30
255.255.255.252
31
255.255.255.254
Parameterization
Default: 0.0.0.0
Default: 0
SCA06 | 18

Advertisement

Table of Contents
loading

Table of Contents