3-6. Extended I/O area
The addresses from F00000h to FFFFFFh are called an extended I/O
area. The ER-A770 uses the following addresses as the break ad-
dress register (BAR) for SSP.
FFFF00h
FFFFFFh
4. LCD display
The ER-770 uses a 320 x 240 dot monochromatic LCD for the main
display and VGAC (MN89303A) for the display controller which is
connected to H8/510 in the ISA bus connection mode.
4-1. Block diagram
Here is the block diagram of the LCD and its allied components.
4-2. LCD panel
The LCD panel uses a dot-matrix liquid crystal module LM320153
with monochromatic STN and COFT backlight. The resolution is 320
x 240.
4-3. Display controller
Matsushita VGAC (MN89303A) is used for display controller.
VRAM is on the address space of the CPU and data can be written
on and read from it by every 128 KB of bank at the address C00000H
C1FFFFH from the CPU side. VRAM consists of 4 banks.
4-4. LCD ON control
The LCD's is bias power supply is controlled by the MN89303A termi-
nal LCDON to turn the LCD screen on and off.
The LCDON is at "L" at resetting +5V power is supplied to the LCD by
setting the expanded function control register bit5 of MN89303A to
"H" with software. The LCD screen isn't turned on until +5V is sup-
plied.
SD0-15
RAS/CAS
SA0-16
WE#
RD#
IORD#
MEMRD#
CPU
H8/510
WR#
IOWR#
MEMWR#
MD0-15
PHAI
CLK
MA0-9
WAIT#
WAIT#
LD0-3
LCDWT
MPCA8
RFSH#
LP
FP
DCLK
MN89303A
LCDON
BACKON
RAS/CAS
WE#
VRAM
DRAM:512KB
D0-15
A0-9
LD0-3
LP
LCD (320X240)
FP
DCLK
VEE
BACKLIGHT
BIAS
INVERTER
Fig. 7
4-5. Back light control
The back light is turned ON/OFF by the MN89303A terminal
BACKON. The initial value is "L" and the back light is off. By setting
the expanded function control register bit6 of MN89303A to "H", the
inverter unit is turned on.
4-6. Luminance and contrast adjustment
Luminance: Luminance is adjusted with an inverter which has dim-
ming function.
Contrast:
Contrast is adjusted by controlling the contrast adjust-
ment voltage (VCON) of the LM320153

5. Customer display

The ER-770 can incorporate a UP-116DP (display tube unit for the
UP-P16DP) for the customer display to carry out the same control as
for the pole display (UP-P16DP).