Symbol/PartsCod)
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
3) IPL from P-ROM via ER-A7RS
(1) Install the two master ROMs to the IC socket (IC12 , IC13) on the
ER-A7RS.
Master ROM -1 : VHI27801RAHxx
Master ROM -2 : VHI27801RAIxx
(2) IPL sitch on the ER-A7RS : Set the IPL SW to ON position.
IPL SW
OFF
ON
(3) Install the ER-A7RS to the ER-A770. (The ER-A770 power should
be turned OFF.)
(4) Turned on the power of the ER-A770.
(5) The buzzer sounds intermittently during the running of IPL and the
program finishes after the buzzer gives five beeps at short inter-
vals.
(6) Turn OFF the power of the ER-A770.
(7) Remove the ER-A7RS from the ER-A770.
(8) Perform the Master reset.
3. Procedure
3.1 POS UTILITY TOOL
No
Procedure on P.C. side
1
Install "POSUTILITYTOOL.EXE" on the P.C.
6
Connect P.C. and ER-A770 (CH2) via RS232. (Fig 1)
MASTER
IC13 ROM2
P-ROM -2
MASTER
IC12 ROM1
P-ROM -1
3. ER-A770 Utility tools
1. Outline
This Specification document describes the explanation about "POSU-
TILITYTOOL.EXEhand "02FD.EXE".
"POSUTILITYTOOL.EXE"and "02FD.EXE" works on Windows 95/98
of PC and they have the following
Functions by connecting ER-A770 with RS232.
POSUTILITYTOOL.EXE : IPL of ER-A770 Program Object
02FD.EXE
2. Environment
PC and ER-A770 are connected by RS232.
Connect the CH2 port of the ER-A770 to the RS-232 interface of the
PC.
RS-232
PC
Fig. 1 Connection between PC and ER-A770
RS232 Cable Connecting:
[PC]
3 TXD
2 RXD
5 S.G.
No
Procedure on ER-A770 side
2
Turn OFF the power.
3
Select "IPL Mode".
Set "IPL Switch" of ER-A770 to "ON".
IPL SW
OFF
ON
4
Turn ON the power.
5
Starting of "IPL Mode".
ER-A770 shows
"IPL from Serial I/O"
IPL from Serial I/O
: All RAM Data Upload/Download
(PC software tool instead of the current
ER-02FD.)
CH2
POS
[ER-A770]
3 TXD
2 RXD
5 S.G.