RS232 I/F Diagnostics
CHANNEL Check
← Display when channel present
CH1 = exist!
CH2 = exist!
← Display when no channel
CH3 = none!
CH4 = none!
CH5 = none!
CH6 = none!
CH7 = none!
(Reference) ER-A7RS CHANNEL setting (In the table below, "1" =
SW OFF, "0" = SW ON.)
ER-A7RS CON3
S1-1
S1-2
S1-3
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
ER-A7RS CON3
S1-4
S1-5
S1-6
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
Terminating procedure
Press the CANCEL key to terminate the check.

2) CH1 Check

Check content
When the channel is not set, an error display is made (ER-
ROR:CH1). When the channel is set, the following check is performed.
Control signal check
ERn
RSn
DRn
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
The read check of the above inputs and the interruption check of
CS, CI, and CD are performed.
In the read check, ER and RS are changed over in the above
sequence and the logic states of DR, CI, CD, and CS are
checked.
If the logic differs from that in the table, an error display is made.
"ON" in the table means Active LOW, and "OFF" means Active
HIGH.
In the interruption check, an interruption of CS, CI, or CD is
allowed one by one. (MASK is canceled.)
If an interruption is not made when each signal is active, or if an
interruption is made when each signal is not active, an error
display is made.
LOGICAL CHANNEL
Invalid
CHANNEL 1: Impossible to set
CHANNEL 2:
CHANNEL 3
CHANNEL 4
CHANNEL 5
CHANNEL 6
CHANNEL 7
LOGICAL CHANNEL
Invalid
CHANNEL 1: Impossible to set
CHANNEL 2
CHANNEL 3
CHANNEL 4
CHANNEL 5
CHANNEL 6
CHANNEL 7
CIn
CDn
CSn
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
ON
ON
ON
The above check is repeated four cycles.
Data transfer check
The loop back data (256 bytes) of 00H ~ 0FFH are used for
data transfer check. The baud rate is set to 38400BPS.
Timer check (RS232 on board timer)
Before performing the check, set the timer to RCVDT start and
5ms. Then perform the following procedure.
During execution of the check, TRQ- must not be generated.
After 5ms from completion of the check, TRQ- must be gener-
ated.
Display
RS232 CH1 Check
ER-DR
:
ERROR!!
All the contents of an error must be displayed.
ERROR
ERROR display
No.
1
ER-DR:ERROR
2
ER-CI:ERROR
3
RS-CD:ERROR
4
RS-CS:ERROR
5
CI INT:ERROR
6
CD INT:ERROR
7
CS INT:ERROR
8
TXEMP:ERROR
9
TXEMP INT:ERROR
10
TXRDY:ERROR
11
TXRDY INT:ERROR
12
RCVRDY:ERROR
13
RCVRDY INT:ERROR RCVRDY interruption is not made.
14
SD-RD:ERROR
15
SD-RD:ERROR
16
TIMER:ERROR
17
TIMER INT:ERROR
Terminating procedure
Press the CANCEL key to terminate the check.

3) CH2 Check

Check content
The check procedure, the display, and the terminating procedure
are the same as CH1 Check.

4) CH3 Check

Check content
The check procedure, the display, and the terminating procedure
are the same as CH1 Check.

5) CH4 Check

Check content
The check procedure, the display, and the terminating procedure
are the same as CH1 Check.

6) CH5 Check

Check content
The check procedure, the display, and the terminating procedure
are the same as CH1 Check.
ERROR content
ER-DR LOOP ERROR
ER-CI LOOP ERROR
RS-CD LOOP ERROR
RS-CS LOOP ERROR
CI interruption is not made.
CD interruption is not made.
CS interruption is not made.
TXEMP is not set.
TXEMP interruption is not made.
TXRDY interruption is not made.
TXRDY interruption is not made.
RCVRDY is not set.
(Reception enabled. TR-Q is
generated during check)
SD-RD LOOP ERROR
(DATA ERROR)
SD-RD LOOP ERROR (DATA
ERROR
TIMER ERROR (TMRQ is not set
after completion of check.)
TRQ-1 interruption is not made.