CONTROL
MODE
6.
CONTROL
MODE
Monitor could be available with respective button, but the DIMMER remain
on.
5.5 Room temperature display (optional)
When the appliance operates with the Room Temperature Display, the
room temperature can be displayed in any mode except Sleep and Dimmer
mode. It will display the setting temperature in 10 sec after receive any
signal from remote control, then display
the Delay time(Setting Timer) display with the Non-real time condition,
include the stand-by state)
Remark: The Room Temperature Display can be available after the
EEPROM parameter selection.
5.6 Auto-restart after blankout
When the appliance loses power during the normal operation, it will
recover with the last setting such as operation mode and temperature
setting, except the air flow direction after power ON.
When the appliance run in normal operation, the Emergent button is
press and hold for over 1.5 sec, and the buzzer beep 2 times, the
Auto-restart after blankout is available.
When the appliance run in normal operation, the Emergent button is
press and hold for over 1.5 sec, and the buzzer beep 1 times, the
Auto-restart after blankout is cancel.
5.7Defrosting mode:
Defrosting starts when it meet one of the following condition1,or 2,or
3,or 4:
1.Need to meet 1.1 and 1.2
1.1The indoor coil temperature below 40°C last for 2min and the
compressor has worked for 50 min;
1.2 After the compressor has worked for 8min, the indoor coil
temperature has dropped more than 5℃ based on the second max point;
2. Need to meet 2.1 and 2.2
2.1The indoor coil temperature below 40°C last for 2min and the
compressor has worked for 80 min;
2.2 After the compressor has worked for 8min, the indoor coil
temperature has dropped more than 4℃ based on the second point;
3. Need to meet 3.1 and 3.2
3.1The indoor coil temperature below 40°C last for 2min and the
compressor has worked for 120 min;
3.2 After the compressor has worked for 8min, the indoor coil
temperature has dropped more than 3℃ based on the second point;
4. Need to meet 4.1
4.1The necessary condition is the compressor has worked exceed
the room temperature. (Only is