6.
CONTROL
MODE
6.
CONTROL
MODE
When the difference between the setting temperature and the room
temperature equal to 2℃ or 4℃, the indoor fan speed will keep in current
speed.
4.2.6 Air flow direction control
The louver is derived by a step motor, and it swings the horizontal louver
automatically. Press the SWING button to swing or stop the louver.
During the louver swing in normal operation, the current position will be
stored. When the appliance turn off and louver swing automatically to the
default position, it will position at the stored position plus 5º.
4.3 Dry mode operation
When the appliance run into the Dry mode, it starts as Cooling mode
operation. If 3 minutes elapses after starting, the appliance will sense the
intake air temperature and minus 2℃ as the setting temperature and
operate in Cooling mode, and the indoor motor speed is low. During this
operation, the air flow direction could be set but the air volume is
unavailable, and the setting temperature can only be adjusted by 2℃ up and
down(the minimum accuracy is 1℃).
When the appliance run in this mode, it will not influenced by under the
18℃ limit.
4.4 Heating mode operation
4.4.1 The 4-way reversing valve is turn ON under the Heating mode.
4.4.2 During this mode operation, the setting temperature and air
volume can be adjusted, and the air flow direction could be swang.
When the appliance run in normal condition, the room's temperature
can only be adjusted by 1℃ up and down base on the setting temperature,
the compressor operation diagram is shown as following.
When the temperature rose, the compressor will be power ON.
High
The setting temp. plus 4℃
Median
The setting temp. plus 2℃
Low