Table 1. Control Mode
Mode
0 (ATX)
1(Auto PWRBTN)
2
3
4
5
6
7
15 (Software
control)
Another function of Smart Mode
1.
If ignition turns back "ON" during "Off" Delay, Power smart function will stay in
operation. "Off" signal will not be send to motherboard. The "Off" Delay will re-start
after next ignition off.
2.
Power input monitoring(before system boot on, during runtime, during soft off delay):
The Power smart function will constantly monitor the input voltage. If the input voltage
is below X Voltage (the standard might have 5% tolerance), the Smart Mode will not
start the power on procedure. When Power smart function has ran in operation and the
battery drops below Y Voltage (with 5% tolerance) more than 10 seconds the Power
smart function will shut down the motherboard following the standard shut down
procedure. If the input voltage recovers in 10 seconds over Y Voltage (with 5%
tolerance) again, the Power smart function will continue to run. (Figure 4)if this
happens, ignition shall be off and on again (Mode 2, 3, 4) or press the remote
switch(Mode 5,6,7) if you want to turn on system again.
Soft OFF
Hard OFF
Delay
delay
No
No
No
No
5 seconds
1 minute
1 minute
5 minutes
30 minutes
2 hours
5 seconds
1 minute
1 minute
5 minutes
30 minutes
2 hours
By user
By user setting
setting
Power ON
Control
Remote Switch
DC ON
Ignition
Ignition
Ignition
Remote Switch
/ Ignition
Remote Switch
/ Ignition
Remote Switch
/ Ignition
By user setting
38
Revision: 1.0
Power OFF Control
Remote Switch
DC OFF
Ignition / Remote Switch
Ignition / Remote Switch
Ignition / Remote Switch
Ignition / Remote Switch
Ignition / Remote Switch
Ignition / Remote Switch
Ignition / Remote Switch