Clearance Dimensions - Fisher & Paykel CG301D Installation Instructions Manual

Gas-on-glass cooktop
Hide thumbs Also See for CG301D:
Table of Contents

Advertisement

I
C
A
A
B
ISO

CLEARANCE DIMENSIONS

Minimum clearance from left edge of cutout to nearest combustible surface
A
Minimum clearance from right edge of cutout to nearest combustible surface
B
Minimum clearance from rear edge of cutout to:
C
Nearest combustible surface
Nearest non-combustible surface
Minimum height of non-combustible material when used on adjacent walls
D
Minimum clearance from cooktop surface to:
E
Rangehood
Any other overhead exhaust fan
Downward facing combustible surface
Downwards-facing tiled or fire resistant surface
Minimum clearance below top of benchtop to:
F
Combustible surface
Fisher & paykel oven or nearest non-combustible surface
Minimum distance from right edge of cooktop to gas connection point on wall
G
(if using a flexible hose)
Distance from floor to gas connection point on wall (if using a flexible hose)
H
Maximum overall depth of overhead cabinetry
I
Note: Ensure there is an earthed power outlet within 900 mm of the centre rear of the product. The gas connector on the wall should be 800-850 mm (H) above the floor and to a distance of at least 250 mm (G) outside the width of
the product, on the right-hand side. It should be accessible with the product installed.
5
CLEARANCE DIMENSIONS
I
C
B
E
E
D
F
F
G
CG301D
CG451D
mm
mm
120
60
120
60
85
85
45
45
150
150
650
650
800
800
650
650
500
500
70
70
65
65
250
250
min. 800 -
min. 800 -
max. 850
max. 850
600
600
D
G
H
H
FRONT
CG752D
CG903D
mm
mm
115
115
115
115
125
125
45
45
150
150
650
650
800
800
650
650
500
500
70
70
65
65
250
250
min. 800 -
min. 800 -
max. 850
max. 850
600
600
8