FIT CLAMPING BRACKETS BASED ON THE
BENCHTOP THICKNESS
Floating nut
Fibre washer
x 4
LPG Models
view from below
Washer
16-20mm
20 mm
!3
CONNECT TO GAS SUPPLY
LPG
Make sure the supply pressure
is regulated to 2.90 kPa, with
all the burners operating at
highest setting.
ALL Models
Make sure the connection point will be accessible with the cooktop installed.
To enable the gas supply to be readily shut o by the customer, make sure the connection
is tted with an isolating valve close to the cooktop.
If connecting the gas with a exible hose:
Ensure the hose is long enough to allow for removal of cooktop for servicing.
Make sure the connector is located as shown in step 5 CLEARANCE DIMENSIONS.
The hose assembly must be certi ed, with an Rp ½" (ISO 7 1) female thread connection.
The hose assembly must be as short as practicable and comply with relevant local code and regulation requirements.
To check that the ignition system operates correctly, light each burner by itself, then all burners in combination.
The hose must not be kinked, subjected to abrasion or permanently deformed.
Check for a well de ned blue ame without any yellow tipping.
If any abnormality is evident, check that the components of the burner assembly are located properly
The hose must not be near or in contact with any hot surfaces
30-40mm
If proper operation cannot be obtained, contact your nearest F&P Authorised Service Centre.
(e.g. base of metal hotlplate, ue, or chassis of underbench oven etc.)
The cooktop must not be used by the customer until proper operation has been achieved.
Elbow (½" BSP external thread)
Make sure to t the supplied
washer and test point adaptor.
Make sure the supply pressure
is regulated to 2.75 kPa, with
the two semi-rapid burners
operating at highest setting.
50 mm
recessed to 50 mm
20-30mm
30-40mm
TG
Adjust to obtain a supply pressure of
1.5 kPa (Hong Kong) or 0.8 kPa (Singapore)
with all the burners operating at the
highest setting.
40mm+
NG Models
Arrow
ALL Models
Make sure the connection point will be accessible with the cooktop installed.
To enable the gas supply to be readily shut o by the customer, make sure the connection
is tted with an isolating valve close to the cooktop.
If connecting the gas with a exible hose:
+50 mm
Ensure the hose is long enough to allow for removal of cooktop for servicing.
40mm+
Make sure the connector is located as shown in step 5 CLEARANCE DIMENSIONS.
The hose assembly must be AS/NZS 1869 Class B or D certi ed, with an Rp ½" (ISO 7 1) female thread connection.
The hose assembly must be no longer than 1.2 m in length with minimum internal
diameter of 10 mm and comply with relevant AS 5601/NZS 5261 requirements.
The hose must not be kinked, subjected to abrasion or permanently deformed.
!4
CHECK ALL CONNECTIONS FOR GAS LEAKS
The hose must not be near or in contact with any hot surfaces
(e.g. base of metal hotlplate, ue, or chassis of underbench oven etc.)
ON
ON
lifting o
!2
SECURE TO BENCHTOP
lifting o
LPG Models
Make sure to t the supplied
regulator.
Adjust to obtain a test point
pressure of 1 kPa with all
burners operating at
highest setting.
Repeat on all the other sides
GAS
GAS
yellow tip
x 4
yellow tip
good ame
Make sure to t the supplied
test point adaptor.
Make sure the supply pressure
is regulated to 2.75 kPa, with all
burners operating at highest
setting.